CAMDEN CV-603 Installation Instructions Manual page 5

Mproxble controller/ mproxble controller cabinet kit
Table of Contents

Advertisement

Bill of material:
Item
Description
1
Controller
2
DC Power Supply
3
Transformer
4
Door Strike, 12 VDC
Door Position Switch, a door latch
5
monitor switch can be used, add
suffix "L" to CX-ED1079
Proximity Card Reader, 125 KHz.
6
Not required if transmitters are
used.
7
Request to Exit Device
System Operation:
a)
The doors are normally locked and closed. The door position switch confirms when the doors are closed.
b)
A user presents a card credential in front of the card reader. The card reader's red LED indicates it is powered. When the credential is
within 2 inches, the reader will beep, and the controller red LED will pulse on 1 second to confirm the credential data was received. If the
controller red LED blinks twice, the credential is being denied by the controller.
c)
If the credential is approved by the controller, the door strike will energize for the pre-set period duration. The door strike will energize
for the full duration of the period until the door is opened and the door position changes state. As soon as the door is opened, the door
strike shall turn off securing the door as soon as it closes.
d)
Users exiting the door, must be detected by the request to exit device; manually by a push switch or automatically using a PIR detector.
Opening the door without a request to exit switch shall cause the controller to generate a door forced open alarm.
e)
Administrators shall use the app to control and configure the CV-603 controller using wireless Bluetooth. A steady on blue LED on the
controller will confirm the connection.
CV-603 MPROXBLE CONTROLLER / CV-603PS-K1 MPROXBLE CONTROLLER CABINET KIT
Camden Model#
Quantity
CV-603PS-K1
1
CV-603 provided in kit
1
60-69B002 - provided in kit
1
CX-TRP-4016 provided in kit
2
CX-ED1079
2
CX-MDA surface or CX-MDH recessed.
2
CV-7400
CM-RQE70 PIR sensor or CM-30E Push
1
button.
INSTAL L AT ION INS T RUCT IONS
Camden Model#
CV-603
CV-603
PS-13
CX-TRP-4016
CX-ED1079
CX-MDA surface or CX-MDH recessed.
CV-7400
CM-RQE70 PIR sensor or CM-30E Push
button.
Page 5 of 20