Bill Of Material; System Operation - CAMDEN CV-603 Installation Instructions Manual

Mproxble controller/ mproxble controller cabinet kit
Table of Contents

Advertisement

Bill of material:

Item
Description
1
Controller
2
DC Power Supply
3
Transformer
4
Alarm Annunciator
5
Door Strike, 12 VDC
Door Position Switch, a door latch monitor switch can be
6
used, add suffix "L" to CX-ED1079
Proximity Card Reader, 125 KHz. Not required if
7
transmitters are used.
8
Request to Exit Device

System Operation:

a)
The door is normally locked and closed. The door position switch confirms when the door is closed.
b)
A user presents a card credential in front of the card reader. The card reader's red LED indicates it is powered. When the credential is
within 2 inches, the reader will beep, and the controller red LED will pulse on 1 second to confirm the credential data was received. If
the controller red LED blinks twice, the credential is being denied by the controller.
c)
If the credential is approved by the controller, the door strike will energize for the pre-set period duration. The door strike will energize
for the full duration of the period until the door is opened and the door position changes state. As soon as the door is opened, the door
strike shall turn off securing the door as soon as it closes.
d)
Users exiting the door, must be detected by the request to exit device; manually by a push switch or automatically using a PIR detector.
Opening the door without a request to exit switch shall cause the controller to generate a door forced open alarm.
e)
An alarm annunciator shall be triggered for the following selected alarm conditions. Relay 2 must be configured for ALARM and Relay 1
configuration must have door contact ON to activate these alarm conditions.
a.
Intrusion
b.
Door not opened after an approved credential read.
c.
Door not closed after access. Alerts managers when the door is being left open.
d.
Anti-passback
e.
Access denied by location – Attempts made by credentials not approved by either reader 1, channel 1, reader 2 or channel 2.
f.
Access denied by schedule.
g.
Unknown user – a credential not enrolled into the controller user data base.
f)
Administrators shall use the app to control and configure the CV-603 controller using wireless Bluetooth. A steady on blue LED on the
controller will confirm the connection.
CV-603 MPROXBLE CONTROLLER / CV-603PS-K1 MPROXBLE CONTROLLER CABINET KIT
Quantity
Camden Model#
CV-603PS-K1
1
CV-603 provided in kit
1
60-69B002 - provided in kit
1
CX-TRP-4016 provided in kit
1
CM-AF142SO
1
CX-ED1079
CX-MDA surface or CX-MDH
1
recessed.
1
CV-7400
CM-RQE70 PIR sensor or
1
CM-30E Push button.
INSTAL L AT ION INS T RUCT IONS
Camden Model#
CV-603
CV-603
PS-13
CX-TRP-4016
CM-AF142SO
CX-ED1079
CX-MDA surface or CX-MDH
recessed.
CV-7400
CM-RQE70 PIR sensor or CM-
30E Push button.