Franklin Electric VersaJet Series Owner's Manual page 6

Shallow well jet pump
Hide thumbs Also See for VersaJet Series:
Table of Contents

Advertisement

Available languages

Available languages

MAINTENANCE
Jet Nozzle & Pressure Switch Adjustments
Jet Nozzle & Pressure Switch Adjustments
Each 60 Hertz VersaJet pump is supplied with three easily replaced jet nozzles. Consult the included
VersaJet Nozzle Installation sheet for further instructions on nozzle switching. Depending on the motor
size on the pump, the supplied nozzles will be marked with A, B, C, or D. Each nozzle, once installed, will
change the performance of the pump according to the data provided. Use the tables below to deter-
mine the correct nozzle.
IMPORTANT: Pressure switch modifications are necessary if the optional Jet Nozzles are installed so
that pump will not run continuously. Continuous operation at shut-off pressure will damage the system.
VersaJet Nozzle Performance Type
Motor HP
Standard
1/2
3/4
1
1-1/2
VersaJet Professional Nozzle Performance Type
Motor HP
Standard
1/2
3/4
1
Changing the Jet Nozzle
1. Remove 3/4" NPT pipe plug.
2. Remove factory installed jet nozzle with the 7/16" Allen wrench provided.
3. Install the desired alternate jet nozzle to change the pump's performance.
4. Tighten the new jet nozzle to 40 in-lbs.
5. Apply a thread sealant and replace the 3/4" NPT pipe plug.
6
High Pressure
B
C
C
D
B
C
B
C
High Pressure
C
D
B
C
B
C
High Flow
A
A
A
A
High Flow
A
A
A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents