5.0

Power Connections

WARNING
WARNING
WARNING
Be certain to connect pump to proper supply voltage. Using incorrect voltage will damage pump and may result in
injury. Voltage requirement is printed on pump serial label.
Input power: 115VAC 50/60 Hz 1.5 amp or 230/240VAC 50/60 Hz 0.7 amp.
Power switch located in Junction Box.
Use voltage your power cord is rated for.
Cord connected models are supplied with a ground wire conductor and a grounding type attachment plug (power
cord). To reduce risk of electric shock, be certain that power cord is connected only to a properly grounded,
grounding type receptacle.
Permanently connected models must be properly grounded. Be certain that a grounding conductor is connected
to terminal T11-1 located in wiring compartment.
Never strap control (input / output) cables and power cables together.
Power Interruption: This pump has an auto-restart feature which will restore pump to operating state it was in
when power was lost.
Note: When in doubt regarding your electrical installation, contact a licensed electrician.
Included cable and conduit connectors:
QTY.
Qty: 2 - .50 Inch (12.7 Mm) Liq-tight Hole Plugs (mat'l = Neoprene), Pre-installed
Qty: 2 - .875 Inch (22.2 Mm) Liq-tight Hole Plugs (mat'l = Neoprene), 2 Pre-installed
Qty: 2 - .50 Inch (12.7 Mm) Liq-tight Connectors For Pass Thru Cords (mat'l = Nylon)
Qty: 2 - .875 Inch (22.2 Mm) Liq-tight Connectors For Pass Thru Cords (mat'l = Nylon)
Qty: 1 - Metallic Liq-tight Connectors For .50 Inch Flexible Conduit (mat'l = Die Cast Zinc), Not Installed
Risk of electric shock – cord connected models are supplied with a grounding
conductor and grounding-type attachment plug. To reduce risk of electric shock, be
certain that it is connected only to a properly grounded, grounding-type receptacle.
Electrical connections and grounding (earthing) must conform to local wiring codes. Be
certain that a grounding conductor is connected to terminal T11-1 located in wiring
compartment.
Risk of electric shock - Disconnect electricity before removing wiring compartment
cover.
WIRING COMPARTMENT COVER
6 in.
(152 mm)
Ø .50
(12.7 mm)
2-PLCS.
DESCRIPTION
Acceptable Cable Diameter .118 To .255 Inch (3.0 To 6.5 Mm), Not Installed
Acceptable Cable Diameter .200 To .395 Inch (5.1 To =10.0 Mm), 1 Pre-installed With Power Cord
Models
Ø .84 in.
(21.3 mm)
3-PLCS.
115V 60Hz
NEMA 5/15 (USA)
max: 125V AC
CHEM-PRO C2F/C3F
POWER CORD OPTIONS
Four power cord plug types available.
Power cord length is 6 feet (3.83 meters)
230V 60Hz
NEMA 6/15 (USA)
max: 250V AC
®
240V 50Hz
CEE 7/VII (EU)
max: 250V AC