How To Operate Chem-Pro - Control Pad - Blue-White ProSeries CHEM-PRO C2F Series Manual

Table of Contents

Advertisement

Page 10
6.0
How to Operate Chem-Pro® - Control Pad
Press and release
Press UP arrow to increase pump speed
(output) in Manual Operation.
To increase value while in programming
mode.
Press and release
Press DOWN arrow to decrease pump
speed (output) in Manual Operation.
To decrease value while in programming
mode.
Press and release
To Stop pump at any time.
Press and release
To Start pump.
To begin listening (reacting) to external signal, such as Remote
Start/Stop.
Press and hold
To enter programming mode.
Ÿ
Remote Start/Stop setup
Ÿ
FVS (flow verification sensor) setup
Press and release
To save setting while in programming mode.
To move to next selection while in programming mode.
Press and release
To prime pump (60 seconds) – See page 17
Time-out - Chem-Pro® pumps have a time-out setting of approximately 20 seconds while in configuration menu. If built-in
timer exceeds 20 seconds without a button being pressed, then pump will exit configuration menu. Changes will only be
saved after START | STOP button is pressed and released.
®