rotork Remote Control Twin Power Manual
rotork Remote Control Twin Power Manual

rotork Remote Control Twin Power Manual

Pneumatic multiturn actuator in standard and atex design

Advertisement

Quick Links

Twin Power
Pneumatic Multiturn actuator in Standard and ATEX design

Mounting

The Twin Power actuator works beyond reproach in all
positions. Valves with fluid media should if possible be
fitted in such a way that fluid leakage from the packing
box is not led from the packing box, through the stem, into
the stem nut and the actuator. It is desirable that the valve
stem should be assembled in an upright position. If this
cannot be done care should be taken to tighten the gland
regularly and change the box packing when necessary.
Grease the drive bush carefully and ensure that there is no
radial or axial diffraction between the drive bush and hub.
Check that the numbers of turns not exceed the permitted
turns on the chosen indicating bridge.
The last three numbers in the type denomination inside
the actuator cover, specifies the type of Indicator Bridge.
Indicator Bridge
Maximum turns
175
3,5 - 18
100
18 - 32
050
32 - 65
175S
65 - 155
100S
155 - 275
050S
275 - 550
In cases where the Twin Power actuator will be assem-
bled on valves with rising stem and rising hand wheel, the
length of the hub must be minimum the length of the drive
bush axially movement.
WARNING!
Hand wheel must only be mounted during manual
operation.
Some practical advice
Ensure that the 3/8" air connections are positioned so as
to prevent dirt and liquids entering the motor. If necessary,
a short length of pipe should be fitted into each port, with
the end pointing downwards.
WARNING!
Twin Power should be handled and operated by skilled
personnel.
www.rotork.com www.remotecontrol.se
Assembly example
Valve designed with rising stem and hand wheel.
Instead of the hand wheel a driving bush with keys is fitted
on the stem end. The driving bush rises axially corre-
sponding to the valve rise. In this case an actuator must
be chosen with a hub length corresponding to the rise of
the bush.
Valve with rising stem and non rising hand wheel.
A flange is mounted on the valve, and a driving bush with
keys fitted in the place of the hand wheel for transmission
of the turning movement to the stem unit.
- 1 -
Top Quality Valve Actuators
Made in Sweden
Manual
Driving
bush
Machined stem
end with key
Driving
bush
Stem nut

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Remote Control Twin Power and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for rotork Remote Control Twin Power

  • Page 1 A flange is mounted on the valve, and a driving bush with keys fitted in the place of the hand wheel for transmission of the turning movement to the stem unit. WARNING! Twin Power should be handled and operated by skilled personnel. www.rotork.com www.remotecontrol.se - 1 -...
  • Page 2 Installation Pressure control The Remote Control Twin Power Actuator is designed for Remove the cover. a normal working pressure of 7 bar (100 psi), but it can be Disconnect the top part of the terminal block, see satisfactorily operated between 4-8 bar (60-140 psi). The figure 1.
  • Page 3 4. Pneumatic signal lamp for open valve Size A4 5. Pneumatic signal lamp for closed valve 6. Mechanical operated 3-way valve (2x) Alternative 3. Piston operated 3-way valve for increased operating speed Air supply Impulse for closing Impulse for opening www.rotork.com www.remotecontrol.se - 3 -...
  • Page 4 To make sure that the setting are sufficient it is recom- mended to operate the actuator a few times. 3:S1/9-10 3:S1/14 2:S1 2:S1/12 3:S1/26 3:S1/41 Figure 3 Figure 2 6:S1/5 6:S1/5 2:S1/5 2:S1/5 2:S1/5 2:S1/5 Figure 4 Figure 5 www.rotork.com www.remotecontrol.se - 4 -...
  • Page 5 The actuator is now synchronized to the valve. Should the actuator ever be removed from the valve, synchronization must be checked after re-installation. The bridge is just an indicating and control device and is not intended to ”stall out” the actuator. www.rotork.com www.remotecontrol.se - 5 -...
  • Page 6 Check that the console (2:S1) oper- ates accordingly to the torque diagram (see technical data sheet). The motor shaft shall actuate outer part of the operating lever. If not, see Adjustment of Indicator Bridge (Page 5). www.rotork.com www.remotecontrol.se - 6 -...
  • Page 7 (normally 4.00 mA). View Figure B Measures not Draw. no. Sheet 004610 tolerance spec. pos. 1. Size A3 4. Mount the gear on the input shaft of the gearbox. View Figure C pos. 2. www.rotork.com www.remotecontrol.se - 7 -...
  • Page 8 We reserve the right to make changes without notice www.rotork.com www.remotecontrol.se Ref No 661C / Art No 980661 ROTORK SWEDEN AB Box 80, Kontrollvägen 15, SE-791 22 Falun, Sweden Tel: +46 (0)23-587 00 • Fax: +46 (0)23-587 45 • falun.info@rotork.com - 8 -...

Table of Contents