Oerlikon Leybold Vacuum Sogevac SV630 B Operating Instructions Manual page 38

Single-stage, oil-sealed rotary vane pump
Table of Contents

Advertisement

Maintenance
=
38
GA02319_002_03 - 07/2007 - © Oerlikon Leybold Vacuum
How to use this v-belt tension meter :
Set the first o-ring at 10 mm on the millimeter scale, as shown figure 8.1,
picture 4, and the other o-ring on position 0 on the Newton scale.
Install the tension meter as shown on picture 3 – figure 8, in the midle,
half-way between the v-belt contacts point of the v-belts and the two pulleys.
Push the Newton scale's black rubber down in order to reach a 10 mm
bending of the v-belt (pictures 2 and 4).
Check the result of your measurement. Tighten the belt tightener to reach
the value given in table below.
The stretching of the V-belts can also be checked with a frequency
meter:
Position the tool on the longest V-belt in its centre and mark this belt.
Place the frequency meter between the motor and generator pulleys,
10 mm above the belts.
Strike the belt and read the frequency (Hz). Refer to the table below for the
rated value.
≈ 10 mm
=
fig. 9

Hide quick links: