Water cooling
The SOGEVAC
pumps are equipped, in standard for the SV630 BF and
®
as an option for the SV630 B/SV750 B, with a water cooling system and a
thermostatic valve. Depending on the local regulations, the cooling water
needed may not be taken from the drinking water mains and max. water
temperatures must be observed. The water cooling connection is made by
an ARGUS type 1/2» x M22 - 150 adapter.
The thermostatic valve regulates the cooling water throughput, and so the
pump temperature. The valve is set in standard on position 1.
Normally, the thermostatic valve should be set somewhere in the range from
1 to 3. Thermostat setting 1 (valve fully open) produces a low operating
temperature of the pump, and setting 3 a high one.
Pumping on vapors requires setting on position 3.
Mean vacuum generator temperature in function of thermostatic valve position setting
100
95
90
85
80
75
70
65
60
55
50
0
Mean vacuum generator temperature in function of thermostatic valve position setting
100
95
90
85
80
75
70
65
60
0
SV630 B water cooled at 50 Hz
100
Pressure (mbar)
SV630 B water cooled at 60 Hz
100
Pressure (mbar)
position 3 with gas ballast
position 3 without gas ballast
position 2 with gas ballast
position 2 without gas ballast
position 1 with gas ballast
position 1 without gas ballast
position 3 with gas ballast
position 3 without gas ballast
position 2 with gas ballast
position 2 without gas ballast
position 1 with gas ballast
position 1 without gas ballast
fig. 5
GA02319_002_03 - 07/2007 - © Oerlikon Leybold Vacuum
Installation
23