Nokia RH-6 Series Rf Description & Troubleshooting page 49

Table of Contents

Advertisement

CCS Technical Documentation
The setup should now look like this:
Select
Manual tuning
Press Manual tuning and a window pops up:
Connect an external signal generator to the RF connector of the phone and set the gen-
erator as told in the window, taking care for external cable losses. If a radio communica-
tion tester (CMD55, CMU200, 8960, MT8801) is used, be sure to have it running in
continuous mode and with modulation switched off.
Issue 1 10/2003
Company Confidential
Input Signal Level
Copyright © 2003 Nokia Corporation.
Company Confidential
7 - RF Description & Troubleshooting
-60
RH-6
Page 49