The setup should now look like this:
Choose respective band (EGSM900, GSM1800, GSM1900).
Press measure. A window pops up, e.g. for EGSM900 band:
Connect an external signal generator to the RF connector of the phone and set the gen-
erator as told in the window, taking care for external cable losses.
Press ok and the window closes.
Read the SNR result. SNR should be:
Page 16
Company Confidential
EGM900 >20dB
GSM1800 >18dB
GSM1900 >18dB