Fluids Hazardous To Health; Personal Protective Equipment; Transport And Storage; Installation - Wilo Rexa MINI3-V-A Series Installation And Operating Instructions Manual

Table of Contents

Advertisement

en
1.4

Fluids hazardous to health

In stagnant water (e.g. pump sump, soakaway,
etc.) germs which are hazardous to health can
form. There is a danger of bacterial infections!
Clean and disinfect the product thoroughly
ƒ
after removal!
Inform all persons about the pumped fluid
ƒ
and the danger it poses!
1.5

Personal protective equipment

Wear the following protective equipment dur-
ing transport, installation, removal and main-
tenance:
Safety shoes: Protection class S1 or P1
ƒ
Protective gloves (EN 388): Category II,
ƒ
marking 3131X
Wear the following protective equipment dur-
ing cleaning operations:
Protective gloves (EN ISO 374-1): Category
ƒ
C
Safety goggles (EN 166): uvex skyguard NT
ƒ
(Identification marking: W 166 34 F CE)
Breathing protection mask (EN 149): 3M
ƒ
Series 6000 with filter 6055 A2
1.6

Transport and storage

Wear protective equipment!
ƒ
Always carry the product by the handle.
ƒ
Never carry or pull on the connection cable!
Clean product and disinfect if necessary!
ƒ
Dirt fosters the formation of germs.
Encrustations may lead to the impeller be-
coming blocked.
1.7

Installation

Wear protective equipment!
ƒ
Do not install damaged or defective
ƒ
products.
If there is a risk of germ formation, observe
ƒ
the following points:
Ensure sufficient air exchange.
Wear a breathing protection mask e.g. 3M
Series 6000 with filter 6055 A2
6
Safety
1.8

Electrical connection

Do not connect products with a damaged
ƒ
connection cable! Have the connection cable
replaced by a qualified electrician or the cus-
tomer service.
Mains connection with correctly installed
ƒ
protective earth conductor.
Install the residual-current device (RCD) with
ƒ
30 mA.
Fuse protection at mains connection: max.
ƒ
16 A.
Product without plug: Electrical connection
ƒ
must be carried out by a qualified electrician!
1.9

During operation

The pumping of highly inflammable and ex-
ƒ
plosive fluids (petrol, paraffin, etc.) in their
pure form is strictly prohibited!
If persons come into contact with the
ƒ
pumped fluid (accessible basins*), do not
commission the product.
*Definition of "accessible basins"
Installation sites that can be walked on and
directly accessed without tools (e.g. ladders):
Garden ponds
ƒ
Paddling pools
ƒ
Cesspools
ƒ
Fountains, etc.
ƒ
NOTICE! The specifications applicable to
swimming pools also apply to accessible
basins.

1.10 Removal

Wear protective equipment!
ƒ
Product without plug: Have the connection
ƒ
cable disconnected from the mains by a
qualified electrician.
Depending on the operating mode and dura-
ƒ
tion, the housing parts become hotter than
40 °C (104 °F).
Only touch the product by the carrying
handle.
Allow product to cool down.
Clean the device thoroughly.
ƒ
WILO SE 2021-01