MULTISPAN UTR 1044 Operating Manual
MULTISPAN UTR 1044 Operating Manual

MULTISPAN UTR 1044 Operating Manual

Universal timer

Advertisement

Quick Links

OPERATING MANUAL
UNIVERSAL TIMER
UTR-1044,2044,444
1
1
SET
ENT

Technical Specification

Model
UPPER:- 4 Digit 7 seg 0.70",red LED Display
Display
LOWER:- 4 Digit 7 seg 0.50",green LED Display
Size(HXWXD)
Panel Cutout
Input
Output
Power Supply
Protection Level
(As per request)
Operating
Temperature
Relative
Humidity
Note
1). For safely purpose, key function are designed in such a way that operator will not go into
detailed parameter setting (Previously Set) function. In this situation, in Password parameter,
YES has to be selected. If previously set parameters are to be changed, then any operator
has to select NO.
2). POWER ON : Timer starts counting as soon as it gets power supply.
3). By default Cycle ON Mode is provided. Please refer programming guide to change to Cycle OFF
Delay ON/ Delay OFF Mode.

Connection Diagram

20
19
18
17
16
+12V
MICRO SWITCH:- M/S Connection 15 & 13
Made in India
~
100
270V AC
!
50/60 HZ
4VA
NO
L
N
1
2
3
4
5
UTR-1044,2044,444
UTR 1044
TIME
3 2 4
234
SET TIME
RESET
UTR 1044
96 X 96 X 50 mm
92 X 92 mm
NPN/PNP Proximity & Micro Switch
1 relay, 2 C/O contact, 230V AC, 5A
100 to 270V AC, 50 / 60 Hz, Approx 4VA
IP-65(Front side) AS per IS/IEC 60529:2001
Up to 95% RH Non Condensing
15
14
13
12
11
NPN
PNP
GND
I/P
I/P
RESET
www.multispanindia.com
Relay
Relay
C
NC
NO
C
NC
6
7
8
9
10
UTR 2044
TIME
1
3 2 4
R
1
234
SET TIME
SET
RESET
ENT
UTR 2044
UPPER:- 4 Digit 7 seg 0.56",red LED Display
LOWER:- 4 Digit 7 seg 0.33",green LED Display
72 X 72 X 85 mm
68 X 68 mm
0°C To 55°C
L
1
~
100
N0
270V AC
50/60 HZ
RELAY
2
N
4VA
!
+12V
3
NC
I/P
4
NPN
MICRO SWITCH:- M/S Connection 4 & 6
I/P
5
N0
PNP
www.multispanindia.com
GND
RELAY
6
RESET
7
NC
Made in India
Page - 1
UTR444
TIME
R1
R2
SET TIME
SET
RESET
ENT
UTR 444
48 X 48 X 95 mm
45 X 45 mm
8
9
C
10
100
~
L
1
270V AC
50/60 HZ
4VA
11
!
N
2
+12V
3
12
www.multispanindia.com
I/P
4
13
C
M/S
PROXI NPN
14
5
GND
Made in India
www.multispanindia.com
NC
8
7
NO
9
RESET
C
10
RELAY
NO
11
6
NC
12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UTR 1044 and is the answer not in the manual?

Questions and answers

Summary of Contents for MULTISPAN UTR 1044

  • Page 1 OPERATING MANUAL UNIVERSAL TIMER UTR-1044,2044,444 UTR 1044 TIME 3 2 4 UTR 2044 TIME 3 2 4 UTR444 TIME SET TIME SET TIME SET TIME RESET RESET RESET Technical Specification Model UTR 1044 UTR 2044 UTR 444 UPPER:- 4 Digit 7 seg 0.70”,red LED Display UPPER:- 4 Digit 7 seg 0.56”,red LED Display...
  • Page 2 Parameter Menu Time 1234 If Delayed ON/ Delayed OFF is selected If Cycling Mode is selected 1234 Press Press Set Time Cycle ON time (time-1) TIM1 Delay time (time-1) TIM1 press key to press key to 1234 1234 set cycle ON time set cycle Delay time Press Cycle OFF time (time-2)
  • Page 3 Working 1). Turn ON instrument. SET time according to your requirement. 2). In running mode, upper display indicates current TIME value and lower display shows SET time value. Relay ON or OFF controls depends on set time. 3). Relay operation is according to selection of Delay ON or Delay OFF in programming menu. 4).
  • Page 4 4) Use and store the instrument within the specified ambient temperature and humidity ranges as mentioned in this manual. Mechanical Installation 136mm - 5.35 inches UTR 1044 TIME 3 2 4 MODEL 50mm...