cable is needed due to different connector type on the Daqu side.
(The cable comes with the Daqu unit.)
Figure 3 and Table 2 defines the pin out of the CAN bus.
Figure 3: Illustration of the pin out of the CAN ports.
Table 2: Description of pins for the CAN bus communication.
3.2.2

Power - POWER

Connect supplied power cable at the back of the instrument. Power
connector has a notch on one side, which protects against wrong
polarity.
Connect blue lead to negative (ground) terminal and red lead to
positive (+12-24 V) terminal.
A 0.5 ampere slow fuse or similar shall be used on the positive lead.
1 ... 8
Pin
Description
1
+12V out.
2
+12V out.
3
+12V out.
4
CAN low.
5
CAN high.
6
GND – ground.
7
GND – ground.
8
GND – ground.
8