Page 3
Raycus pulsed fiber laser is classified as a high power Class IV laser device. Before supplying the power to the device, please make sure that the correct voltage of 24V DC is connected and the anode and cathode are right.Incorrect polarityor voltage will harm...
The figure of Raycus P30MX pulse fiber laser is shown in Figure 2 The laser is pumPing by the way of fiber coupling output semiconductor laser, so the efficiency of pump light conversion is very high.The laser uses air cooling system and thefan can change speed in real time according to the...
Page 6
Caution: Make sure the corresponding wires of the device are properly grounded. All the maintenance to the device should only be done by Raycus, because there is no replacement or accessory provided with the device. Please do not try to damage the labels or open the cover in order to prevent against electric shock, or the warranty will be invalid.
Wuhan Raycus Fiber Laser Technologies CO., Ltd. P30MX Pulsed Fiber Laser User’s Guide V1 1.4. Specifications Technical Data are shown in Table 2. The possible pulse repetition rates (PRR) and the maximum average energy P for different duration are given in the Table 3 .To give a quick overview the dependencies according to Figures 4, 5 and 6 (which show the shape of the average power)and Figures 7 and 8(which show the pulse ...
Page 8
Wuhan Raycus Fiber Laser Technologies CO., Ltd. P30MX Pulsed Fiber Laser User’s Guide V1 Table 2 P30MX pulsed fiber laser specifications Characteristic Test condition Typ. Max. Unit Pulsed Mode of operation Polarization Random Maximum pulse energy 500ns/30kHz/30W Nominal average output power...
Page 9
Wuhan Raycus Fiber Laser Technologies CO., Ltd. P30MX Pulsed Fiber Laser User’s Guide V1 Figure 4 Relation between pulse repetition rate PRR and maximum average power P ns ns ns ns ns ns ns ns ns ns ns ns 1000...
Page 10
Wuhan Raycus Fiber Laser Technologies CO., Ltd. P30MX Pulsed Fiber Laser User’s Guide V1 ns ns ns ns ns ns ns ns ns ns ns ns pulse repetition rate PRR[kHz] Figure 6 Relation between pulse repetition rate PRR and maximum average power P forvarious pulse duration ...
Page 11
Wuhan Raycus Fiber Laser Technologies CO., Ltd. P30MX Pulsed Fiber Laser User’s Guide V1 ns ns ns ns ns ns ns ns ns 50ns ns ns pulse repetition rate PRR[kHz] Figure 8 Relation between pulse repetition rate PRR and maximum average power E...
Wuhan Raycus Fiber Laser Technologies CO., Ltd. P30MX Pulsed Fiber Laser User’s Guide V1 2.2. Method of installation Fix the module stable to the bracket and keep the laser in good ventilation. Connect the power line to 24VDC power and ensure enough DC output power. Keep it...
Wuhan Raycus Fiber Laser Technologies CO., Ltd. P30MX Pulsed Fiber Laser User’s Guide V1 3. Control Interface There are DB9 andDB25 interfaces at the rear of the laser. The DB9 is a RS232 interface only used for debugging, no needs to connect. And DB25 is the joint interface connecting control system to the laser system,please make sure the connection is reliable before operation.
Page 16
Wuhan Raycus Fiber Laser Technologies CO., Ltd. P30MX Pulsed Fiber Laser User’s Guide V1 T1 represent the initialization time of the laser machine. The initialization time is less than 10s from power-on to perform initialization. T2 represent the pump recharge time, usually around 5ms.
Page 17
Wuhan Raycus Fiber Laser Technologies CO., Ltd. P30MX Pulsed Fiber Laser User’s Guide V1 Table 7 Laser duration control signal Name Description The setting of the data bits synchronize with rising edge of Serial input theserial clock. Serial clock Serial clock, frequency range: 10kHz~1MHz.
Wuhan Raycus Fiber Laser Technologies CO., Ltd. P30MX Pulsed Fiber Laser User’s Guide V1 For example, if using Beijing JCZ Technology Co. marking card to adjust laser pulse duration, the setting processes are described as follows: Make sure the power supply, DB25 cable, control card and computer are correctly connected, and then turn on the 24V power supply.
Wuhan Raycus Fiber Laser Technologies CO., Ltd. P30MX Pulsed Fiber Laser User’s Guide V1 4.3. Cautions Marking frequency must be in the range of 1 kHz to 2000 kHz. It should not modify the frequency while marking. Stop marking first before shutting down the device, then turn the power down to zero and cut the power off.
Raycus has the right to choose to repair or replace any product that proves to be defective in materials and workmanship selectively during the warranty period. Only products with particular defects are under warranty.