Summary of Contents for Ultimate Healthcare Viola II UPRA1717-2
Page 1
Viola II Dynamic Cushion Replacement System UPRA1717-2 and UPRA2020-2 _________________________________________________ User Manual Issue 9 – 17/12/2020 UPRA1717-2+UPRA2020-2.UM-9...
Contents Introduction ............................4 Intended Use ............................ 4 2.1 Contraindications ........................4 About the Product ..........................4 Symbols and Statements ......................... 6 Important Safety Information ......................7 Technical Specification ........................8 6.1 Power unit ..........................8 6.2 Cushion ............................ 8 Installation and Set-Up........................
User Manual. Note: Ultimate Healthcare reserves the right to modify the information in this User Manual at any time. The information in this User Manual may vary slightly with respect to the basic design of the product.
Page 5
Cushion UPRA1717-2 Removable Cover Foam Insert Cell retaining band 6 x Standard Cells Air Pipe Connector UPRA2020-2 Removable Cover Cell retaining band 7 x Standard Cells Air Pipe Connector Page 5 of 20 Issue 9– 17122020...
Power Unit Swing Out Power Connection Hooking Hooks ON/OFF Switch Air Pipe Connection Point Control Panel 4. Symbols and Statements Note: Indicates tips and advice for the correct use of this product. Caution: Indicates correct operating or maintenance procedures in order to prevent damage to or destruction of the product or other property.
Use only the cleaning and disinfectant agents recommended in this User Manual. When connecting product after transportation or storage, inspect the power cable visually for any signs of damage. If evident, do not use product and contact Ultimate Healthcare or your local distributor for repair.
6. Technical Specification Power unit Dimensions: 280mm x 145mm x 130mm (D x W X H) Weight: 2.4 kg Alternating cycle time: 10 mins Output pressure range: 30 to 70mmHg (+/-5) Power supply: AC 230V 50 Hz Current: 0.12 A Classification: Class I, Type BF Warranty:...
7. Installation and Set-Up Setting up Cushion For the comfort and safety of the patient do not put them onto the cushion until system indicates that it is fully inflated. The cushion is designed to completely replace any existing cushion which may be in use on a bed.
8. Control Panel Operation Guide The Control Panel of the power unit is used to make adjustments to the cushion replacement and also indicates fault conditions. These are either visual (indicator lights) or audible. Static Mode Indicator Comfort Control Dial Function Mode Selection Button Normal Pressure Indicator Alternating Mode Indicator...
When the dial is turned towards Soft, the output pressure will be decreased to provide a lower pressure output and thus increased comfort. To check if the pressure is adequately supporting the patient, slide one hand between the cushion replacement and chair cushion to feel under the patient’s bottom. You should be able to slide the hand in-between and an acceptable range is approximately 25 to 40 mm (1”...
If not, turn the Mode dial to switch to alternating mode. Ensure that the power unit is resting against a solid Power unit is noisy surface. If the problem persists, contact Ultimate Healthcare or your local service provider. Page 12 of 20 Issue 9– 17122020...
Healthcare cannot be held liable for. Caution: The appropriate qualified staff must be consulted when specifying a suitable cleaning fluid. Ultimate Healthcare shall not be liable for any damages caused by the use of inappropriate detergents or disinfectants. 12.2 Cushion and cover disinfection...
12.3 Power unit disinfection The power unit can be cleaned by wiping down with a cloth dampened with hot water at 60 containing detergent or with sodium hypochlorite (up to 10,000 parts per million available chlorine). 12.4 Cover laundering The cushion cover and air pipe cover can also be machine washed. Cushion covers and air pipe cover should be completely removed prior to laundering.
14 Service and Maintenance It is recommended that this product be part of a routine preventative maintenance schedule with a planned service every 12 months regardless of product usage. 14.1 General (1) Check power cable and plug if there are abrasions or excessive wears. (2) Check cushion cover for signs of wear or damage.
15 EMC Information Recommended separation distances between portable and mobile RF communications equipment and the ME equipment TheAlternating Pressure Air Flotation Mattress is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of theAlternating Pressure Air Flotation Mattress can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications Alternating Pressure Air Flotation Mattress equipment (transmitters) and the...