H7GP
Characteristics
Insulation resistance
Dielectric strength
Impulse withstand voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
EMC
Approved standards
Case color
Weight
4
100 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min between current-carrying terminal and exposed non-current-carrying
metal parts (AC model)
1,000 VAC, 50/60 Hz for 1 min between current-carrying terminal and exposed non-current-carrying
metal parts (DC model)
2,000 VAC, 50/60 Hz for 1 min between power terminals and control input terminals (AC model)
3 kV (between power terminals) (1 kV for 12-to-24-VDC models)
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) (1.5 kV for
12-to-24-VDC models)
1.5 kV (between AC power terminals), 480 V (between DC power terminals),
480 V (between input terminals);
square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
Display:
Malfunction: 8 kV
Destruction: 15 kV
DIP switch: Malfunction: 4 kV
Destruction: 8 kV
Destruction: 10 to 55 Hz with 0.75-mm single amplitude each in three directions
Malfunction: 10 to 55 Hz with 0.5-mm single amplitude each in three directions
2
Destruction: 294 m/s
(30G) each in three directions
2
Malfunction: 196 m/s
(20G) each in three directions
Operating: –10 C to 55 C (with no icing)
Storage:
–25 C to 65 C (with no icing)
Operating: 35% to 85%
(EMI):
Emission Enclosure:
Emission AC Mains:
(EMS):
Immunity ESD:
Immunity RF-interference:
Immunity Conducted Disturbance:
Immunity Burst:
UL508, CSA22.2 No.14, conforms to IEC61010-1/EN61010-1, EN50081-2, EN50082-2,
VDE0106/P100
Rear section: Gray smoke; Front section: 5Y7/1 (light gray) or N1.5 (black)
Approx. 76 g
EN50081-2
EN55011 Group 1 class A
EN55011 Group 1 class A
EN50082-2
EN61000-4-2:4 kV contact discharge
8 kV air discharge
ENV50140:
10 V/m (Amplitude-modulated, 80 MHz to 1 GHz)
10 V/m (Pulse-modulated, 900 MHz)
ENV50141:
10 V (0.15 to 80 MHz)
EN61000-4-4:2 kV power-line
2 kV I/O signal-line
H7GP