Explosion-proof SL pumps (without cooling
jacket), installation type S, must always be
completely submerged in the pumped
liquid to the top of the motor. See fig.
Liquid levels, level 1.
For explosion-proof SE pumps (with
cooling jacket), installation type C, the
pump housing must always be completely
covered by the pumped liquid. See fig.
Liquid levels, level 2.
For a short period, the pump may be used
to pump down the liquid level to remove
the float layer. For explosion-proof pumps,
do not let it go below the stop levels shown
in fig. Liquid levels.
To ensure adequate motor cooling, the following
minimum requirements must be met:
Installation type S: the pump must be completely
submerged in the pumped liquid to the top of the
motor. See fig. Liquid levels, level 1.
Installation type C: the pump housing must be
completely covered by the pumped liquid. See fig.
Liquid levels, level 2.
Liquid levels
Installation types D and H:there are no special
requirements for the level of the pumped liquid.
1
2
17