DANGER
Crushing hazard
Death or serious personal injury
Pumps with installation type S, C and
pressure range S, H are delivered with
a mounted lifting eye and an additional
shackle, which must be used to attach
the hook and the chain correctly.
When lifting the pump, use the right lifting
point to keep the pump balanced for
proper installation. The table below shows
the correct lifting point.
Installation
Pressure
type
range
S, H
S, C
M, L, E
S, H, M, L,
D
E
S, H, M, L,
H
E
The following installation types must be lifted at the
lifting bracket:
types S with pressure range M, L and E
types C with pressure range M, L and E
type D.
See fig. Lifting points, vertical installation, pos. 1.
The following installation types must be lifted at the
lifting eye with shackle (at the back of the lifting
bracket):
types S with pressure range S and H
types C with pressure range S and H.
See fig. Lifting points, vertical installation, pos. 2.
Installation type H can be lifted by a hole in the flange
and the middle lifting point. See fig. Lifting points,
horizontal installation.
12
Lifting
bracket
Lifting point
assembly
Pos. 2, see
with lifting
fig. Lifting
eye and
points,
shackle
vertical
installation
Pos. 1, see
fig. Lifting
no lifting
points,
eye
vertical
installation
Pos. 1, see
fig. Lifting
no lifting
points,
eye
vertical
installation
See fig.
Lifting
no lifting
points,
eye
horizontal
installation
1
Lifting points, vertical installation
Lifting points, horizontal installation
2