Introduction; Technical Features - Scale House FPW Series Installation And Operating Manual

Pallet-weighers
Table of Contents

Advertisement

Available languages

Available languages

1. INTRODUCTION

All the weighing modules of the FPW series are constructed with quality materials and a calibration procedure
that guarantees the maximum reliability and durable weighing precision. Weighing elements are made up of 4
load cells, produced in conformity with the OIML R60 International Recommendation.
The two platforms' cell are equalized through junction box, complete of screened 6-pole cable, approximately 3
meters long, for the connection to the weight indicator.
All FPW series' modules have been projected and constructed with a wide margin of safety, also in particularly
adverse environment conditions.
The FPW series' pallet-weighing modules have been studied for industrial and commercial applications, in
which it's necessary to weigh rapidly transported material on moving wagons; the available capacities are 1500
and 3000 kg.

1.1 TECHNICAL FEATURES

Load cells
SHEAR BEAM
Max. tolerated power supply voltage
5/12 VDC
Nominal output (nickeled steel cell)
2 o 3 mV/V +/- 0,25% (depending on the model)
Combined error
< 0,03 % FSO
Temperature compensation
-10°C / +40°c
Work temperature
-35°C / +65°C
Cells' electrical resistance
Input
350 Ohm +/- 3.5
Output
350 Ohm +/- 3.5
6