FIRE OR EXPLOSION HAZARD
• Failure to follow safety warnings exactly could result in
serious injury, death or property damage.
• Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone
in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
• Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
READ AND KEEP THIS MANUAL FOR REFERENCE
Printed in Canada
HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL
COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier
designed to reduce the risk of burns from the hot viewing glass is provided
with this appliance and shall be installed for the protection of children and
other at-risk individuals. NOTE : Barrier required, may be sold separately.
WARNING
(FG00004)
MULTIFONCTION REMOTE (MF)
(FG00007)
GAS FIREPLACE HEATER
We suggest that our gas hearth products
be installed and serviced by professionals
who are certified in the U.S. by the
National Fireplace Institute (NFI) as NFI
Gas Specialist.
DANGER
WARNING
• If not installed, operated and maintained in accordance
with the manufacturer's instructions, this product could
expose you to substances in fuel or from fuel combustion
which can cause death or serious illness.
• This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA only) or
mobile home, where not prohibited by local codes.
• This appliance is only for use with the type of gas
indicated on the rating plate.
• This appliance is not convertible for use with other
gases, unless a certified kit is used.
• Fuels used in gas, wood-burning or oil fired appliances, and
the products of combustion of such fuels, contain chemicals
known to the State of California to cause cancer, birth defects
or other reproductive harm. For more information go to
www.P65warnings.ca.gov/
OWNER'S
MANUAL
S42 MODEL
PROFLAME II VERSION
MILLIVOLT VERSION
DIRECT VENT
ZERO CLEARANCE
46166U_A
2021-02-12

Advertisement

Table of Contents
loading

Summary of Contents for Valcourt S42

  • Page 1 OWNER’S MANUAL S42 MODEL (FG00004) PROFLAME II VERSION MULTIFONCTION REMOTE (MF) (FG00007) MILLIVOLT VERSION DIRECT VENT ZERO CLEARANCE GAS FIREPLACE HEATER We suggest that our gas hearth products Safety tested be installed and serviced by professionals according to ANSI Z21.88-2017 who are certified in the U.S.
  • Page 2 REFERENCE FOR THE OWNER Information concerning your fireplace Model: ____________________________________ Date of purchase/installation : ________________ Serial Number : ____________________________ Fireplace location: _________________________ Dealer : ___________________________________ Dealer’s phone number : ____________________ Notes: _______________________________________________________________________________...
  • Page 3 If it cannot be provided, the warranty period will be determined by the date of manufacture of the product. It is also highly recommended to register the warranty online at https://www.valcourtinc.com/en/warranty/warranty-registration/ Registering the warranty will help to quickly find the information needed on the unit. Owner’s Manual - S42 Page 3...
  • Page 4: Table Of Contents

    Lighting Instructions (Millivolt Model) ................. 14 4. Operating Instructions ......................15 Noise coming from the fireplace ..................16 First operation ......................... 16 Control (Proflame II model) ....................17 Control (Millivolt model) ....................24 Standing Pilot Operating Instructions ................25 Page 4 Owner’s Manual - S42...
  • Page 5 Control System Troubleshooting (Millivolt) ................. 37 8. Parts View ans Parts List Proflame II model (FG00003) ............40 9. Parts View ans Parts List Millivolt model (FG00006) ............43 Appendix 1: Accessories ......................46 Waranty ............................ 47 Owner’s Manual - S42 Page 5...
  • Page 6: Certification Plate

    • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Page 6 Owner’s Manual - S42...
  • Page 7: Safety Information

    Do not abuse the glass by striking or hitting it. WARNING Do not use ammonia based or abrasive cleaners on glass. Do not attempt to clean glass when glass is hot. Owner’s Manual - S42 Page 7...
  • Page 8: Carbon Monoxide Poisoning Hazard

    After it has been determined that each appliance connected to the venting system properly vents when tested as outlined above, return doors, windows, exhaust fans, fireplace dampers and any other gas-fired burning appliance to their previous conditions of use. Page 8 Owner’s Manual - S42...
  • Page 9: Safety Information For Users Of Propane Gas

    Odorants in Propane Gas also are subject to oxidation. This fading can occur if there is rust inside the storage tank or in iron gas pipes. Owner’s Manual - S42 Page 9...
  • Page 10 Always be sure your container is under vapor pressure by turning it off at the container before it goes completely empty or having it refilled before it is completely empty. Page 10 Owner’s Manual - S42...
  • Page 11: General Information

    Do not put furniture or any other combustible hosehold Be careful not to put any decorating objects objects within 36" of the fireplace front. sensitive to heat too close above or around the fireplace was it gets very hot when operating. Owner’s Manual - S42 Page 11...
  • Page 12: Fuel

    Odor risk with polymer materials Do not install any cement boards of other materials that contain polymer based fibers or other polymer materials. 3. Lighting Instructions Page 12 Owner’s Manual - S42...
  • Page 13: Lighting Instructions (Proflame Ii Model)

    TO TURN OFF GAS TO APPLIANCE Turn off all electric power to the appliance Locate On/Off gas shut-off and turn if service is to be performed (if applicable). clockwise to OFF. Do not force. Owner’s Manual - S42 Page 13...
  • Page 14: Lighting Instructions (Millivolt Model)

    Turn off all electric power to the appliance if service Push in gas control knob slightly and turn clockwise is to be performed (if applicable). to “OFF.” Do not force. Remove barrier screen. Replace barrier screen. Set REMOTE/OFF/ON switch to OFF. Page 14 Owner’s Manual - S42...
  • Page 15: Operating Instructions

    NOTICE: The variable speed blower feature will not operate during a power outage. NOTICE: Replace all batteries at least once each year, preferably before at the beginning of the season. Owner’s Manual - S42 Page 15...
  • Page 16: Noise Coming From The Fireplace

    It is normal for your gas fireplace to give off some odor the first time it is burned. This is due to the curing of the paint and oil from the manufacturing process. Please ensure that your room is well ventilated - open a window. Page 16 Owner’s Manual - S42...
  • Page 17: Control (Proflame Ii Model)

    Control (Proflame II model) With a multifunction thermostatic Remote (Transmitter) ON/OFF/SMART Button Technical Data - Remote Control Supply voltage 4.5 V (three 1.5 V AAA batteries) Ambient temp. ratings 0-50°C (32 - 122°F) Radio frequency 315 MHz Owner’s Manual - S42 Page 17...
  • Page 18 With the batteries already installed in the transmitter, push the ON/OFF button. The receiver will beep four times to indicate the transmitter’s command is accepted and sets to the particular code of that transmitter. The system is now initialized. Page 18 Owner’s Manual - S42...
  • Page 19 Turn OFF the Fireplace With the system ON, press the ON/OFF button on the transmitter. The transmitter LCD display will only show the room temperature. At the same time, the receiver will turn off the fireplace. Owner’s Manual - S42 Page 19...
  • Page 20 A single beep will confirm reception of the command. Flame OFF Flame Level 1 Flame Level 5 Flame Level Maximum Page 20 Owner’s Manual - S42...
  • Page 21 LCD screen of the transmitter. Note: When Smart Thermostat is activated, manual flame height adjustment is disabled. Owner’s Manual - S42 Page 21...
  • Page 22 This function will lock the buttons to avoid unsupervised operation. To activate this function, press the MODE and UP buttons at the same time. To deactivate this function, press the MODE and UP buttons at the same time. Page 22 Owner’s Manual - S42...
  • Page 23 • Turn the system power supplies (to the wall control or remote control) OFF for two or three seconds and then restoring a power supply back on. • The return of the system to normal operation must be checked under safe conditions by the user and/ or service personnel. Owner’s Manual - S42 Page 23...
  • Page 24: Control (Millivolt Model)

    “HI” to increase the flame height and clockwise to “LO” to decrease the flame height. When the heating season ends, turn the REMOTE/OFF/ON switch to “OFF” and the control knob to “OFF”. The system, including the pilot light, will be shut down. Page 24 Owner’s Manual - S42...
  • Page 25: Standing Pilot Operating Instructions

    To ignite main burner, turn the control knob on the gas valve from the PILOT position to the ON position. Turn the Remote/OFF/ON switch from the OFF position to the ON position. The additional green wire and red wire, which are stripped and bare are not used. Owner’s Manual - S42 Page 25...
  • Page 26: Maintenance And Service

    Grasp the top of the DETAIL A barrier and pull forward to disengage it. Remove the barrier by pulling straight forward. Page 26 Owner’s Manual - S42...
  • Page 27: Glass Cleaning

    (which is normal) forms on the inside of the glass and causes lint, dust and other airborne particles to cling to the glass surface. Also initial paint curing may deposit a slight film on the glass. Use a non- abrasive household cleaner and warm water (we recommend gas fireplace glass cleaner). Owner’s Manual - S42 Page 27...
  • Page 28: General

    • The fireplace and venting system should be inspected before initial use and at least annually by a qualified service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the air flow. Page 28 Owner’s Manual - S42...
  • Page 29: Inspection

    • Keep burner and control compartment clean. • Examine venting system periodically and replace damaged parts. • Make a periodic visual check of pilot and burners. Clean and replace damaged parts. Owner’s Manual - S42 Page 29...
  • Page 30 - Inspect the venting and vent termination cap for damage, corrosion, sooting, or obstruction and correct if present. - Check all accessible gas-carrying tubes, connections, pipes and other components for leaks. - In addition, clean and inspect the fireplace following any remodeling work in your home. Page 30 Owner’s Manual - S42...
  • Page 31: Gas Valve

    If the gasket located under the burner cover is damaged during service, it must be replaced before reinstalling the burner in place. Refer to section «8. Parts View and Parts List», page 40 to properly install the gasket. Owner’s Manual - S42 Page 31...
  • Page 32 «6. Invisimesh Barrier and glass door removal», page 26. them aside in a safe location. It is not necessary to remove decorative glass media from the burner cover or decorative panels to gain access to the control module. Page 32 Owner’s Manual - S42...
  • Page 33: Maintenance Frequency

    • Any control should be replaced if it does not perform properly on checkout or service. In addition, replace any module if it is wet or looks like it has been wet. Owner’s Manual - S42 Page 33...
  • Page 34: Maintenance Venting

    NOTICE: This also pertains to vertical vent systems installed on the outside of the building. Venting termination shall not be recessed into a wall or siding. Slide the vertical vent cap over the ends of the vent pipe and secure Page 34 Owner’s Manual - S42...
  • Page 35: Control System Troubleshooting (Proflame Ii)

    Clogged or dirty burner ports Clean burner ports Blocked orifice Check orifice opening Burner does not light but Loose wire connections Check valve/control module connections pilot remains on Faulty pilot Replace pilot Faulty valve Replace valve Owner’s Manual - S42 Page 35...
  • Page 36 Whistle noise from fireplace Open control knob to full position position Spiral gas flex line pinched or Straighten flex line where pinched or replace too small diameter line gas feed line with larger diameter Page 36 Owner’s Manual - S42...
  • Page 37: Control System Troubleshooting (Millivolt)

    (continued on the next Thermopile may page) not be generating Be sure the wire connections from the thermopile at the gas sufficient millivolts. valve terminals are tight and the thermopile is fully inserted into the pilot bracket. Owner’s Manual - S42 Page 37...
  • Page 38 The maximum improperly pitched. downwards slope is 1/4 inch. Bad thermopile or Replace if necessary. thermocouple. Improper vent cap Check for proper installation and freedom from debris or installation. blockage. Page 38 Owner’s Manual - S42...
  • Page 39 Make sure that vent system joints are tight and Flame burns blue and Insufficient oxygen have no leaks. lifts off main burner. being supplied. Check to make sure that no material has been placed at the main burner base. Owner’s Manual - S42 Page 39...
  • Page 40: Parts View Ans Parts List Proflame Ii Model (Fg00003)

    8. Parts View and Parts List Proflame II model (FG 00004) WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this fireplace may result in property damage or personal injury. Page 40 Owner’s Manual - S42...
  • Page 41 ELECTRICAL BOX 60201 CONNECTOR 1 SCREW 3/8" FOR BX WIRE PL71192 COVER PLATE ACCENT LIGHT 21561 ACCENT LAMP GASKET w/PSA PL71238 NAILING FLANGE PL71228 BACKER STUD PL71239 LINER BRACKET 21538 AIR INTAKE FLUE GASKET Owner’s Manual - S42 Page 41...
  • Page 42 PL71248 RIGHT PANEL 22405 RIGHT PANEL (AC04310) AC04311 3 RUSTIC BRICK PANELS (S42) 22350 LIGHTHOUSE RUSTIC REAR LINER FOR S42 22351 LIGHTHOUSE RUSTIC LEFT LINER FOR S42 22352 LIGHTHOUSE RUSTIC RIGHT LINER FOR S42 22398 LOG F - S42 KIT...
  • Page 43: Parts View Ans Parts List Millivolt Model (Fg00006)

    9. Parts View and Parts List Millivolt model (FG 00007) WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this fireplace may result in property damage or personal injury. Owner’s Manual - S42 Page 43...
  • Page 44 SE44080-01 RHEOSTAT 3.0 AMP - 115 VAC WIRE WITH CONNECTOR 44087 RHEOSTAT NUT 44085 RHEOSTAT KNOB 44000 ELECTRICAL BOX 60201 CONNECTOR 1 SCREW 3/8" FOR BX WIRE PL71192 COVER PLATE ACCENT LIGHT 21561 ACCENT LAMP GASKET w/PSA PL71238 NAILING FLANGE PL71228 BACKER STUD Page 44 Owner’s Manual - S42...
  • Page 45 PL71248 RIGHT PANEL 22405 RIGHT PANEL (AC04310) AC04311 3 RUSTIC BRICK PANELS (S42) 22350 LIGHTHOUSE RUSTIC REAR LINER FOR S42 22351 LIGHTHOUSE RUSTIC LEFT LINER FOR S42 22352 LIGHTHOUSE RUSTIC RIGHT LINER FOR S42 22398 LOG F - S42 KIT...
  • Page 46: Appendix 1: Accessories

    APPENDIx 1: ACCESSORIES The following accessories must be purchased separately. Their installation instructions are included in their kit and can be found on Valcourt website, in the options/Accessories section of this fireplace’s page. Description Color Code REQUIRED ACCESSORIES 5 porcelain panels...
  • Page 47: Waranty

    **Exclusion refer to statement above. ***Labour based on predetermined chart. Shall your unit or a component be defective, contact immediately your dealer or VALCOURT customer service. Prior to your call make sure you have the following information necessary to your warranty claim treatment: •...
  • Page 48 This document is available for free download on the Stove Builder International inc. manufacturer’s website. It is a copyrighted document. 250, rue de Copenhague, Resale is strictly prohibited. The manufacturer may update St-Augustin-de-Desmaures (Québec) Canada this document from time to time and cannot be responsible G3A 2H3 for problems, injuries, or damages arising out of the use 418-908-8002...

Table of Contents