•
First Digit Wait Timer (seconds): Program First Digit Wait Timer in
this field. Range of First Digit Wait Timer is from 01 to 99 seconds. By
default, it is 06 seconds.
•
Rx Gain (db): Program Rx Gain in this field. Valid options for Rx Gain
are:
•
-1.5
•
0
•
+1.5
•
+3
By default, Rx Gain is 0.
•
Tx Gain (db): Program Tx Gain in this field. Valid options for Tx Gain
are:
•
-1.5
•
0
•
+1.5
•
+3
By default, Tx Gain is 0.
•
AC Impedance (Ohm): Program AC Impedance in this field. Valid options
for AC Impedance are:
•
600 ohm
•
900 ohm
•
Complex
By default, 600 ohm is selected.
•
Minimum Current for Off-hook Detection (mA): Program minimum
current for Off-hook detection on FXS Port in this field. You can select
one of the following options:
•
10mA
•
12mA
•
14mA
•
16mA
•
18mA
By default, Minimum Current for Off-hook Detection is 12 mA.
•
On-hook Detection Current: Program current to detect On-hook
condition on FXS Port in this field. You can select one of the following
options:
•
10mA
•
12mA
•
14mA
Need help?
Do you have a question about the SIMADO GFX44 and is the answer not in the manual?