Page 1
(FireProtect Plus) is a wireless indoor �re detector with an in-built buzzer and a battery, ensuring up to 4 years of autonomous operation. FireProtect can detect smoke and rapid temperature increase. Aside from these functions, FireProtect Plus additionally can alert of dangerous CO level.
The system noti�es the user of all events through push noti�cations, SMS, and calls (if activated). The Ajax security system can be connected to a central monitoring station of a security company. Buy �re detector FireProtect Functional Elements 1. Siren hole 2.
Page 3
60°С), the detector registers temperature increase, which triggers a �re alarm. The life span of the FireProtect Plus detector lasts up to 7 years (up to 10 years for the FireProtect ). In the event of a detector failure, you will receive a corresponding noti�cation —...
Page 4
2. Through the Ajax app. In case of �re alarm, you will see a pop-up message in Ajax app suggesting to turn off the built-in sirens. 3. Using the KeyPad KeyPad Plus (if Interconnected FireProtect Alarms feature is enabled). To turn off the built-in sirens in case of �re alarm, press the “*”...
Page 5
Fire Alarm command for this button in the KeyPad/KeyPad Plus settings. If smoke and/or temperature levels do not restore to normal values, in 10 minutes, the FireProtect/FireProtect Plus turns on the siren again. Connecting the Detector to the Ajax Security System...
Page 6
3. Tap Add — the countdown will start. 4. Switch on the device. To make sure that the detector is on, press the on/off button — the logo will light up red for a second. For detection and pairing to occur, the detector should be located within the coverage area of the wireless network of the hub (at a single protected object).
Page 7
The smoke detector always operates in the active mode. When connecting FireProtect to third party security systems, it is appropriate to place it in a permanently active protection zone. States 1.
Page 8
Firmware Detector �rmware version Device ID Device identi�er Settings 1. Devices 2. FireProtect | FireProtect Plus 3. Settings Setting Value First �eld Device name, can be edited Selecting the virtual room to which the device is...
Page 9
Switches the device to the signal strength test Jeweller Signal Strength Test mode FireProtect Self Test Starts FireProtect selftest Allows the user to disconnect the device without removing it from the system. Two options are available: Entirely — the device will not execute system...
Page 10
5. Go to the Fire detectors settings menu and activate the Interconnected FireProtect Alarms option Interconnected alarms are supported by FireProtect and FireProtect Plus detectors with �rmware versions 3.42 and later. Please note that when you turn on the interconnected alarms, you cannot set the hub–detector ping interval (Jeweller settings) of more than 48...
Page 11
4. An alarm con�rmation event is sent to the monitoring station and security system users, and the system starts the interconnected alarm for �re detectors if: The interconnected alarm delay time has passed, and the triggered detector is still registering an alarm. 00:00 00:14 During the delay of the interconnected alarms, the triggered detector reports a...
Page 12
During the interconnected alarm delay, another �re detector in the system raised an alarm. 00:00 00:11 To give more time to eliminate the cause of false triggering of the detector, the user can delay the propagation of the interconnected alarm for another 10 minutes: Through Ajax apps.
Page 13
By pressing the KeyPad/KeyPad Plus function button (in the interconnected �re alarm muting mode). By pressing the Button in the interconnected �re alarm muting mode. By eliminating the cause of the alarm (�re detectors at the facility no longer detect an alarm). By pressing the touch button of the triggered �re detector.
(CR2) Two short sound signals per 90 sec — backup Battery low battery low (CR2032) Three short sound signals per 90 sec — both batteries low Performance testing The Ajax security system allows conducting tests for checking the functionality of...
(the logo center) for a few seconds – the detector will test the smoke chamber with electronic simulation of smoke generation and then will switch on the siren for 6 seconds. You will receive the noti�cation in the Ajax app regarding the test result and detector status. Installation...
If there are any beams at the ceiling, protruding by 30 or more centimeters from the ceiling level, install the detector between every two beams. How to install FireProtect �re detector correctly Where and how to install FireProtect Plus Installation procedure...
Page 17
If LED doesn’t blink after �xing in SmartBracket, check the status of the tamper in Ajax app and then the �xing tightness of the panel. If someone detaches the detector from the surface or takes it off the attachment panel, the security system noti�es you.
Maintenance and Battery Replacement Check the operational capability of the detector regularly. Clean the detector body from dust, spider web, and other contaminants as they appear. Use soft dry napkin suitable for tech equipment. Do not use any substances containing alcohol, acetone, gasoline, and other active solvents to clean the detector.
Page 19
Tamper protection 868.0 – 868.6 MHz or 868.7 – 869.2 MHz Frequency band depending on the region of sale hubs Operates independently or with all Ajax range extenders ocBridge Plus Compatibility uartBridge Maximum RF output power Up to 20 mW...
4. Battery CR2032 (pre-installed) — 1 pcs 5. Installation kit 6. Quick Start Guide Warranty Warranty for the “AJAX SYSTEMS MANUFACTURING” LIMITED LIABILITY COMPANY products is valid for 2 years after the purchase and does not apply to the pre-installed battery.
Need help?
Do you have a question about the FireProtect and is the answer not in the manual?
Questions and answers