7.7 List of parameters different from FR-A700
Parameter
Function name
52
DU/PU main display data selection
54
CA terminal function selection
68
Retry waiting time
71
Applied motor
83
Rated motor voltage
84
Rated motor frequency
96
Auto tuning setting/status
158
AM terminal function selection
178
STF terminal function selection
179
STR terminal function selection
180
RL terminal function selection
181
RM terminal function selection
182
RH terminal function selection
183
RT terminal function selection
184
AU terminal function selection
185
JOG terminal function selection
186
CS terminal function selection
187
MRS terminal function selection
188
STOP terminal function selection
189
RES terminal function selection
190
RUN terminal function selection
191
SU terminal function selection
192
IPF terminal function selection
193
OL terminal function selection
194
FU terminal function selection
195
ABC1 terminal function selection
196
ABC2 terminal function selection
291
Pulse train I/O selection
292
Automatic acceleration/deceleration
306
Analog output signal selection
Analog meter voltage output
310
selection
313
Y0 output selection
314
Y1 output selection
315
Y2 output selection
316
Y3 output selection
317
Y4 output selection
318
Y5 output selection
319
Y6 output selection
320
RA1 output selection
321
RA2 output selection
322
RA3 output selection
450
Second applied motor
456
Rated second motor voltage
800
Control method selection
838
DA1 terminal function selection
Regeneration avoidance operation
883
level
FR-A770 DEDICATED SPECIFICATIONS
Item
A770-79
Setting range
Without "9"
Setting range
Without "9"
Setting range
0 to 600s
Setting range
0 to 8, 13 to 18
Initial value
Setting range
10 to 120Hz
Setting range
Without "11"
Setting range
Without "9"
Setting range
Without "10, 11, 70, 71"
Without "7, 46, 57, 85, 107,146,
Setting range
157, 185"
Setting range
Without "10, 11, 20, 21, 100"
Setting range
Without "11"
Setting range
Without "9"
Setting range
Without "9"
Without "7, 46, 57, 85, 107, 146,
Setting range
157, 185"
Setting range
Without "7, 46, 57, 85"
Setting range
0 to 8, 13 to 18, 9999
Initial value
Setting range
Without "13, 14"
Setting range
Without "9"
Setting range
300 to 1200V
Initial value
0 to 8, 13 to 18, 20, 23, 24, 30,
33, 34, 40, 43, 44, 50, 53, 54,
330, 333, 334, 8093, 8094
200V class: 200V
690V
400V class: 400V
With "10, 11, 70, 71"
With "7, 46, 57, 85, 107,
With "10, 11, 20, 21, 100"
With "7, 46, 57, 85, 107, 146,
With "7, 46, 57, 85"
0 to 8, 13 to 18, 20, 23, 24, 30,
33, 34, 40, 43, 44, 50, 53, 54,
200V class: 200V
690V
400V class: 400V
200V class: 380V
1080V
400V class: 760V
A700
With "9"
With "9"
0 to 10s
10 to 300Hz
With "11"
With "9"
146,157, 185"
With "11"
With "9"
With "9"
157, 185"
9999
With "13, 14"
With "9"
300 to 800V
32