Parameter
Name
C2
Terminal 2 frequency
setting bias frequency
(902)
C3
Terminal 2 frequency
setting bias
(902)
125
Terminal 2 frequency
setting gain frequency 0 to 400Hz
(903)
C4
Terminal 2 frequency
setting gain
(903)
C5
Terminal 4 frequency
setting bias frequency
(904)
C6
Terminal 4 frequency
setting bias
(904)
126
Terminal 4 frequency
setting gain frequency
(905)
C7
Terminal 4 frequency
setting gain
(905)
C8
Current output bias
signal
(930)
C9
Current output bias
current
(930)
C10
Current output gain
signal
(931)
C11
Current output gain
current
(931)
C12
Terminal 1 bias fre-
quency (speed)
(917)
C13
Terminal 1 bias
(speed)
(917)
C14
Terminal 1 gain
frequency (speed)
(918)
C15
Terminal 1 gain
(speed)
(918)
*1
Setting can be made only when the FR-A7AP/FR-A7AL is mounted.
*2
Parameters cannot be copied from FR-A720 or FR-A740.
Setting Range
Initial Value
0 to 400Hz
0Hz
0 to 300%
0%
60Hz
0 to 300%
100%
0 to 400Hz
0Hz
0 to 300%
20%
0 to 400Hz
60Hz
0 to 300%
100%
0 to 100%
0%
0 to 100%
0%
0 to 100%
100%
0 to 100%
100%
0 to 400Hz
0Hz
0 to 300%
0%
0 to 400Hz
60Hz
0 to 300%
100%
Parameter
Name
Terminal 1 bias com-
C16
mand (torque/mag-
(919)
netic flux)
C17
Terminal 1 bias
(torque/magnetic flux) 0 to 300%
(919)
Terminal 1 gain com-
C18
mand (torque/mag-
(920)
netic flux)
C19
Terminal 1 gain
(torque/magnetic flux) 0 to 300%
(920)
Terminal 4 bias com-
C38
mand (torque/mag-
(932)
netic flux)
C39
Terminal 4 bias
(torque/magnetic flux) 0 to 300%
(932)
Terminal 4 gain com-
C40
mand (torque/mag-
(933)
netic flux)
C41
Terminal 4 gain
(torque/magnetic flux) 0 to 300%
(933)
989
Parameter for manufacturer setting. Do not set.
990
PU buzzer control
PU contrast
991
adjustment
Droop break point
994
gain
Droop break point
995
torque
Automatic parameter
999
setting
Pr.CL
Parameter clear
ALLC
All parameter clear
Er.CL
Faults history clear
*2 Parameter copy
PCPY
PARAMETER
Setting Range
Initial Value
0 to 400%
0%
0%
0 to 400%
150%
100%
0 to 400%
0%
20%
0 to 400%
150%
100%
0, 1
1
0 to 63
58
0.1 to 100%,
9999
9999
0.1 to 100%
100%
10, 11, 20, 21,
9999
30, 31, 9999
0, 1
0
0, 1
0
0, 1
0
0, 1, 2, 3
0
24