PARAMETER
Parameter
Name
58
Restart cushion time
Remote function
59
selection
Energy saving control
60
selection
61
Reference current
Reference value at
62
acceleration
Reference value at
63
deceleration
Starting frequency for
64
elevator mode
65
Retry selection
Stall prevention
66
operation reduction
starting frequency
Number of retries at
67
fault occurrence
68
Retry waiting time
Retry count display
69
erase
71
Applied motor
73
Analog input selection 0 to 7, 10 to 17
Input filter time
74
constant
Reset selection/
disconnected PU
75
detection/PU stop
selection
Alarm code output
76
selection
Parameter write
77
selection
Reverse rotation
78
prevention selection
Operation mode
79
selection
80
Motor capacity
Number of motor
81
poles
Motor excitation
82
current
83
Rated motor voltage
Rated motor
84
frequency
Speed control gain
89
(magnetic flux vector)
90
Motor constant (R1)
91
Motor constant (R2)
92
Motor constant (L1)
93
Motor constant (L2)
94
Motor constant (X)
Online auto tuning
95
selection
Auto tuning setting/
96
status
17
Setting Range
Initial Value
0 to 60s
1s
0, 1, 2, 3
0
0, 4
0
0 to 3600A,
9999
9999
0 to 220%, 9999
9999
0 to 220%, 9999
9999
0 to 10Hz, 9999
9999
0 to 5
0
0 to 400Hz
60Hz
0 to 10,
0
101 to 110
0 to 600s
1s
0
0
0 to 8, 13 to 18
0
1
0 to 8
1
0 to 3, 14 to 17,
100 to 103, 114
14
to 117
0, 1, 2
0
0, 1, 2
0
0, 1, 2
0
0, 1, 2, 3, 4, 6, 7
0
0.4 to 3600kW,
9999
9999
2, 4, 6, 8, 10, 12,
14, 16, 18, 20,
9999
9999
0 to 3600A,
9999
9999
0 to 1000V
400V
10 to 120Hz
60Hz
0 to 200%, 9999
9999
9999
0 to 400m ,
9999
9999
0 to 3600m ,
9999
(0 to 400mH),
9999
9999
0 to 100 ,
(0 to 100%),
9999
9999
0 to 2
0
0, 1, 101
0
Parameter
Name
V/F1 (first
100
frequency)
V/F1 (first
101
frequency
voltage)
V/F2 (second
102
frequency)
V/F2 (second
103
frequency
voltage)
V/F3 (third
104
frequency)
V/F3 (third
105
frequency
voltage)
V/F4 (fourth
106
frequency)
V/F4 (fourth
107
frequency
voltage)
V/F5 (fifth
108
frequency)
V/F5 (fifth
109
frequency
voltage)
Third
110
acceleration/
deceleration time 0 to 3600/360s,
Third
111
deceleration time
Third torque
112
boost
Third V/F (base
113
frequency)
Third stall
114
prevention
operation current
Third stall
prevention
115
operation
frequency
Third output
116
frequency
detection
PU communication
117
station number
PU communication
118
speed
PU communication
119
stop bit length
PU communication
120
parity check
Number of PU
121
communication retries 0 to 10, 9999
PU communication
122
check time interval
PU communication
123
waiting time setting
PU communication
124
CR/LF selection
Terminal 2 frequency
125
setting gain frequency
Terminal 4 frequency
126
setting gain frequency
Setting Range
Initial Value
0 to 400Hz,
9999
9999
0 to 1000V
0V
0 to 400Hz,
9999
9999
0 to 1000V
0V
0 to 400Hz,
9999
9999
0 to 1000V
0V
0 to 400Hz,
9999
9999
0 to 1000V
0V
0 to 400Hz,
9999
9999
0 to 1000V
0V
9999
9999
9999
0 to 30%, 9999
9999
0 to 400Hz,
9999
9999
0 to 220%
150%
0 to 400Hz
0
0 to 400Hz
60Hz
0 to 31
0
48, 96, 192, 384
192
0, 1, 10, 11
1
0, 1, 2
2
1
0, 0.1 to 999.8s,
9999
9999
0 to 150ms,
9999
9999
0, 1, 2
1
0 to 400Hz
60Hz
0 to 400Hz
60Hz