19.2 Overview of spare parts

20
Item
Designation
20
Seat
www.gemu-group.com
Material
see order code (order
data)
103 / 108

19.3 Replacement of spare parts

▶ Assembly instructions for replacing the wearing parts are
included with every wearing parts kit.
1
C
18
19
20
21
22
1. Undo and remove the hexagon screws 22.
2. Remove the seat retainer 21.
3. Remove and replace the seat 20.
4. Assembly in reverse order.

20 Removal from piping

1. Disassemble the product. Observe warning notes and
safety information.
2. Remove in reverse order to installation.

21 Disposal

1. Pay attention to adhered residual material and gas diffu-
sion from penetrated media.
2. Dispose of all parts in accordance with the disposal regu-
lations/environmental protection laws.