Warmington SG-EG 600 Installation Instructions Manual page 19

Retro fitted gas open fire
Hide thumbs Also See for SG-EG 600:
Table of Contents

Advertisement

ADJUSTMENT OF HI / LOW PRESSURE - SG ONLY
Note: Control Valves are factory set but may require adjustment onsite
Turn Appliance off & remove front plastic cover on Igniter. Pull cover to slide off.
Unscrew test nipple on the burner manifold & fit the test gauge securely - see diagram.
To set the High: Light the burner & turn to high - then adjust the high screw to the desired pressure - see spec's.
To set the Low: Light the burner & turn to low - then adjust the low screw to the desired pressure - see spec's.
Extinguish Appliance, remove test equipment and secure test nipple.
Check valve & burner for correct operation & check fire for gas leaks.
ADJUSTMENT OF THE PILOT - 3 FLAME for BOTH SG & EG
Note: When the base screw is removed, gas will leak from the out let, ensure that the pilot is
not adjusted or the screw is removed when the fire is burning.
Adjustment of Pilot - 3 Flame: Unscrew base screw as shown in Diagram 2.
Insert a screwdriver as shown in Diagram 3 and adjust the adjustment screw up inside
the 3 Flame Pilot to adjust the flame height.
The flame must always be passing over the Electrodes &/or File Tube on either side.
Replace the Base screw and check for leaks.
3 Flame Pilot in
assembled state
Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.
19
2
All Dimension are in mm.............Copyright ©
Adjusted by Gasfitter ONLY
Adjusted by Gasfitter ONLY
3
29 March 2021
Note: to Gasfitters
The 3 flame pilot may need adjustment
after a period of running time on set up
as the increase in heat in the fire will
induce a higher draft in the fire, and
may pull in flame away from the File
Tube causing the fire to shut down.
Correct operation of
3 Flame Pilot