UNPACKING & SETUP PACKING LIST • Scale • Manual • C9V 600mA Power Adapter UNPACKING & ASSEMBLY 1. Place the scale in the desired location and level the platform 2. Lift the stainless steel platform off the base 3. Adjust the feet to center the level bubble.
Page 5
INSTALLATION OF OPTIONAL POLE PACKING LIST Fig. 1 • Pole • Screw and Nut Sets • U-Shape Indicator Bracket with 2 Knobs Fig. 2 • Indicator Bracket UNPACKING Fig. 3 & ASSEMBLY 1. Remove the stainless steel platter from the scale platform. 2.
INDICATOR DISPLAY Capacity: 30lb x 0.01lb / 15kg x 0.005kg Legal for Trade 334BS30 PRINT UNIT TARE ZERO SETUP FUNC TOTAL DATA PRESET ON/OFF • - Scale is zeroed, gross weight is 0, tare is 0. • - Scale is stable.
FUNCTION KEYS NOTE: Normally, the 2nd function of a key needs to be pressed down for > 3 sec. to be activated. PUSH DEFINITION MODE TIME Enters or Exits HOLD Mode <3 Seconds Weighing, Counting, or Percent Mode Enters SETUP Mode >3 Seconds HOLD Returns to last sub-menu...
OPERATIONS & SETTINGS NORMAL WEIGHING MODE 1. Power on the scale by pressing the ZERO/ON/OFF key. 2. If the display stabilizes but doesn’t show zero, press the ZERO/ON/OFF key to set new zero point. 3. Place the objects on the scale platform and read the weight on the indicator. Note: Objects should be placed at the center of the platform.
Page 10
CHECK WEIGHING (DATA COMPARE) The check weighing or data compare function allows the user to input a pre-set range, and the display will indicate whether the weighed value is within that range, and indicate if it is too high or too low. 1.
COUNTING MODE & CHECK COUNTS IN COUNTING MODE Disabled for Legal-for-Trade applications. WORK WITH UPS WORLDSHIP Set scale port to NCI3835 in UPS worldship. TROUBLESHOOTING SYMPTOM PROBABLE CAUSE SOLUTION Re-plug the AC adapter or rotate the plug AC Adapter is not connected securely to securely connect it to the scale Scale does not Low battery...
Page 12
SYMPTOM PROBABLE CAUSE SOLUTION Re-set CONFIG parameters per the CONFIG parameters are not correctly set manual CAL parameters are not correctly set Re-calibrate the scale USER parameters are not correctly set Re-set USER parameters per the manual Input data or loaded weight is too small, Input correct data, load correct weight or too big onto platform...
Need help?
Do you have a question about the 334BS30 and is the answer not in the manual?
Questions and answers