These parameters are available:
1. Modem and GPRS
a.
PIN code
b.
GPRS APN
c.
User
d.
Password
2. INPUT1 , INPUT2
a.
Sensitivity
b.
Contact type
c.
Event code
d.
Reporting
3. Monitoring station 1 and 2
a.
IP address
b. Port
c.
Protocol
d. SIA prefix
e.
Object identifier
f.
Replace
obtained identifier
g.
Dialed number
by alarm system
h. Link test period
SC-GPRS
Alarm Monitoring Communicator v1.3
Settings of network connection
Enter the PIN code for the SIM card, if necessary
Access Point Name provided by GSM operator
User name provided by GSM operator, if necessary
Password provided by GSM operator, if necessary
Independent signalling contact inputs
Minimum length of time of physical contact
NC type input must be disconnected from the ground to activate
NO type input must be shorted to ground to activate
CID event code that will be sent when input is activated
Destination monitoring receivers in possible logical order
(only MS1, MS1 and MS2, MS1 or MS2, only MS2)
IP address of monitoring receiver
Dedicated port number for monitoring receiver
UDP or TCP/IP
Needed if the alarm system object identifier is 4 character,
and the monitoring software expects 6 characters
The communicator individual identifier
When the communicator receiving the CID format from the
alarm system and before send it to the monitoring receiver, is to
replaces the own identifier in event code.
If the dialed number fits this value, the communicator sends the
received CID report to this Monitoring Station. If these fields are
BLANK, MS1 is primary and MS2 is backup.
Periodic test data report to the monitoring receiver.
Device will send a „test report" to that receiver in intervals set in this
field