BAE SA-CS-027-YI-BP00,3 GS04
IO-Link Sensor Amplifier
5
Installation and connection
5.1
Assembling the amplifier
The following fitting methods are available:
–
Simple clamp fitting on the hat rail acc. to DIN, 35 mm
or 15 mm
–
Screw fixing with pan-head M3 screws
5.2
Connecting the amplifier
The amplifier can be operated with type BCS...-XXS-...
sensors.
Fig. 5-1:
Connecting the sensor
5.3
Electrical Connection
1
2
4
3
Fig. 5-2:
Plug layout (top view of M12 plug)
Pin Color
Signal
1
BN
L+ (Operating voltage +, SIO 10...30 V,
IO-Link 18...30 V)
2
WH
Teach line
3
BU
L− (Operating voltage −)
4
BK
C/Q output signal
Tab. 5-1:
Pin assignment
Teach-in mode is only useful in SIO mode.
In normal operation, the white teach line must
always be connected to the blue negative line.
www.balluff.com
5.4
SIO mode
PNP
BN
+
3
BK
OUT
BU
–
WH
ext. prog.
NPN
BN
+
3
BK
OUT
BU
–
WH
ext. prog.
Fig. 5-3:
SIO mode (PNP/NPN)
5.5
IO-Link operation
BN
1
+
3
BK
4
OUT
BU
3
–
WH
2
ext. prog.
Fig. 5-4:
IO-Link operation
+
1
4
–
3
2
+
1
4
–
3
2
+
C/Q
–
Master
english
9