Operating Mode; Overview Of Menu Structure; Analog Sensor Value (In Digits); Teaching In Switchpoints - Balluff IO-Link BAE SA-CS-027-YI-BP00,3 GS04 User Manual

Table of Contents

Advertisement

Available languages

Available languages

BAE SA-CS-027-YI-BP00,3 GS04
IO-Link Sensor Amplifier
7

Operating mode

In operating mode, trained staff can adjust all functions.
Switching hysteresis is fixed at 15 digits.
Calling up operating mode
During parameterization via IO-Link or if the IO-
Link parameter AccessLock Userinterface is
activated, operating mode is locked.
► Press and hold the
button for at least 8 s.
⇒ The remaining time is shown in the display (in
seconds).
⇒ The first menu item (
i n
in digits).
Navigating the menu
Taste
Funktion
Browse menu items at the
same level.
und
Select parameters within a
menu item
Switch to parameter input
within a menu item.
Exit parameter input mode.
Switch to the main menu.
Change to a submenu item.
Returning to the submenu
activates the most recently
used submenu item.
Change to a submenu item.
Returning to the submenu
activates the most recently
used submenu item.
Tab. 7-1:
Navigating the menu
Exiting operating mode
► Confirm
with the
End
⇒ All settings are saved; the display indicates
the sensor dampening rate in digits. After
10 minutes of inactivity, the operating mode is
exited without saving any teach values.
www.balluff.com
) is displayed (analog value
Anzeige
Yellow
LED segments
Orange
LED
segments
Yellow
segments
flash
Yellow
segments
light up
[ ]
button.
and
run
7.1

Overview of menu structure

Ebene
Display
1
2
1
Analog sensor value (in
i
n88888
digits)
2

Teaching in switchpoints

t
S88888
3
Manually adjusting
SP
18888
switchpoint 1
4
Manually adjusting
SP28888
switchpoint 2
5
Submenu: Configuration
[
8
]c onf
Adjusting the switching
a
out
8888
power amplifier type
Adjusting the switching
b
Mod8888
mode
c

Setting external triggers

E t t
8888
Setting the switch-on
d
don8888
delay
Setting the switch-off
e
dof
8888
delay
6
Submenu: Display
[
8
]di SP
settings
Display of software
g
F
W88888
version
Display of hardware
h
HW88888
version
i
Adjusting the luminosity
L
uM8888
Display text rotation
j
1808888
(0/180°)
Dampening rate display
k
VaL8888
in RUN mode
7
Closing the menu
E
nd8888
Tab. 7-2:
Menu structure
7.2

Analog sensor value (in digits)

i n
Indicates a value dependent on the sensor, distance
(relative measurement), or dampening.
Display range: 0...4095
Function
Section
7.2
7.3
7.4
7.5
7.6
7.6.1
7.6.1
7.6.2
7.6.3
7.6.4
7.7
7.7.1
7.7.1
7.7.2
7.7.3
7.7.4
7.8
english
11