Relay Networking Mode Use - Ebyte E96-DTU User Manual

Hide thumbs Also See for E96-DTU:
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co.,Ltd.
1. Forwarding rules, the relay can forward data in both directions between two NETIDs.
2. In the relay mode, ADDH\ADDL is no longer used as a radio address, but as a NETID forwarding pairing.
As shown in the figure:
①First level relay
"Node 1" NETID is 08.
"Node 2" NETID is 33.
The ADDH\ADDL of relay 1 are 08 and 33 respectively.
So the signal sent by node 1 (08) can be forwarded to node 2 (33)
At the same time, node 1 and node 2 have the same address, so the data sent by node 1 can be received by node 2.
②Secondary relay
The ADDH\ADDL of relay 2 are 33 and 05 respectively.
So relay 2 can forward the data of relay 1 to the network NETID: 05.
Therefore, node 3 and node 4 can receive node 1 data. Node 4 normally outputs data, and node 3 has a different address
from node 1, so no data is output.
③Two-way relay
As shown in the configuration: the data sent by node 1 can be received by nodes 2 and 4, and the data sent by nodes 2
and 4 can also be received by node

9 Relay Networking Mode Use

The following figure shows the display interface of the E96-DTU (400SL30-485) configuration host computer. The
user can switch to the configuration mode through the MODE button, and quickly configure and read the
parameters on the host computer.
Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
E96-DTU(400SL30-485) User Manual
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

400sl30-485

Table of Contents