Factory Default Parameters; Relay Networking Mode Use - Ebyte E96-DTU User Manual

Hide thumbs Also See for E96-DTU:
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co.,Ltd.
07H
Write
08H
Write
80H~
Read
86H

7.3 Factory Default Parameters

Product model
Radio model
E96-DTU(400SL22-485
)

8 Relay Networking Mode Use

Serial number
1
2
3
4
Description of relay networking rules:
Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
High byte of key (default 0)
CRYPT
_H
Low byte of key (default 0)
CRYPT
_L
Product information 7 bytes
PID
Frequency
Address
433.125M
0x0000
Hz
After setting the relay mode through the configuration mode, switch to the normal mode, and the
relay starts to work.
In the relay mode, ADDH and ADDL are no longer used as the radio address, but correspond to
the NETID forwarding pairing respectively. If one of the networks is received, it will be
forwarded to the other network. The network ID of the repeater itself is invalid.
In the relay mode, the relay station cannot send and receive data, and cannot perform low-power
operation.
When the user enters other modes from Mode 3 (sleep mode) or is in the reset process, the radio
will reset the user parameters, during which AUX outputs low level.
500ms
1000ms
1500ms
2000ms
2500ms
3000ms
3500ms
4000ms
Factory default parameter value:C0 00 00 62 00 00
Channel
Air rate
0x17
2.4kbps
Relay mode description
E96-DTU(400SL30-485) User Manual
Cycle T= (1+WOR)*500ms, the
maximum is 4000ms, the minimum is
500ms;
The longer the WOR monitoring interval
period, the lower the average power
consumption, but the greater the data
delay;
Both sender and receiver must agree
(very important)
Only write, read returns 0;
Used for encryption to avoid interception
of wireless data in the air by similar
radio stations;
The radio station will use these two bytes
as a calculation factor to transform and
encrypt the wireless signal in the air.
Product information 7 bytes
Serial
Baud rate
format
9600
8N1
Transmit
power
30dBm (small
power)
16

Advertisement

Table of Contents
loading

This manual is also suitable for:

400sl30-485