Download Print this page

Backyard Pro Patio Series Operation Instructions Manual page 15

Tower patio heater
Hide thumbs Also See for Patio Series:

Advertisement

OPERATION INSTRUCTIONS
OPERATION INSTRUCTIONS
4. If the pilot lights, keep control knob pressed for 15 seconds then
3.Check for pilot flame through glass tube. If pilot does
turn the control knob to 'LOW'.
not light, turn control knob to 'OFF' position wait two
5. For maximum heat, turn control knob to 'HIGH'.
minutes minimum and try again from the start. Some
6. To turn heater off, turn control knob to 'OFF'.
attempts may be necessary.
7. Close the vlave of the gas cylinder or the regulator after use.
4.If the pilot alight, keep control knob pressed for 15
seconds then turn the control knob to 'LOW'.
5.For maximum heat turn control knob to 'HIGH'.
6.To turn heater off, turn control knob to 'OFF'.
7.Close the vlave of the gas cylinder or the regulator after
use.
CLEANING AND MAINTENANCE:
CLEANING AND MAINTENANCE
To enjoy outstanding performance of your heater for years make sure to perform the following
To enjoy outstanding performance of your heater for years, make sure to perform the following
maintenance activities on a regular basis:
maintenance activities on a regular basis:
● Keep exterior surfaces clean.
• Keep exterior surfaces clean.
-Use warm soapy water for cleaning. Never use flammable, corrosive or abrasive cleaners.
• Use warm soapy water for cleaning. Never use flammable, corrosive or abrasive cleaners.
-While washing your unit, be sure to keep the area around the burner and pilot assembly dry at all
• While washing your unit, be sure to keep the area around the burner and pilot assembly
time. If the gas control is exposed to water in any way, do NOT try to use it. It must be replaced.
dry at all time. If the gas control is exposed to water in any way, do NOT try to use it. It
● After a long break from operation, the unit should be inspected for spiders, spider webs or other
insects.
must be replaced.
● Air flow must be unobstructed. Keep controls. Burner and circulating air passageways clean.
• After a long break from operation, the unit should be inspected for spiders, spider webs or
Signs of possible blockage include:
other insects.
-Gas odour with extreme yellow tipping of flame.
• Air flow must be unobstructed. Keep controls, burner, and circulating air passageways clean.
-Heater does NOT reach the desired temperature.
-Heater glow is excessively uneven.
SIGNS OF POSSIBLE BLOCKAGE INCLUDE:
-Heater makes popping noises.
● Spider and insects can nest in burner or orifices.
• Gas odor with extreme yellow tipping of flame.
This dangerous condition can damage heater and render it unsafe for use. Clean burner holes by
• Heater does NOT reach the desired temperature.
using a heavy-duty pipe cleaner.
• Heater glow is excessively uneven.
Compressed air may help clear away smaller particles.
• Heater makes popping noises.
● Carbon deposits may create a fire hazard. Clean reflector and glass tube inside with soapy water
• Spider and insects can nest in burner or orifices. This dangerous condition can damage
if any carbon deposits develop. Always be careful when cleaning the glass tube.
heater and render it unsafe for use. Clean burner holes by using a heavy-duty pipe cleaner.
Compressed air may help clear away smaller particles.
• Carbon deposits may create a fire hazard. Clean reflector and glass tube inside with soapy
water if any carbon deposits develop. Always be careful when cleaning the glass tube.
HI
OFF
LO
OFF
LIGHT
LOW
HIGH
15

Advertisement

loading

This manual is also suitable for:

554hpsqrss554hpsqrstl554hpsqrbz554hpsqrblk