Removing And Replacing Frus; Removing Ac Power Supplies - Cisco Catalyst 8500 Series Hardware Installation Manual

Edge platforms
Hide thumbs Also See for Catalyst 8500 Series:
Table of Contents

Advertisement

Removing and Replacing FRUs

This chapter describes procedures for removing and replacing field-replaceable units (FRUs) from Cisco
Catalyst 8500 Series Edge Platform.

Removing AC Power Supplies

Procedure
Step 1
Ensure that the chassis power switch is in the Standby position.
Note
Step 2
Unplug the power cable from the power supply.
Step 3
Press the retaining latch towards the pull handle, grasp the handle with one hand, and pull the power supply
out of the slot while supporting the weight of the power supply with the other hand.
Step 4
Repeat these steps if it is required to remove the other AC power supply.
It is not required to place the chassis power switch in the Standby position if you want to hot-swap
a single power supply.
C H A P T E R
Cisco Catalyst 8500 Series Edge Platforms Hardware Installation Guide
4
37