Atlantic 200L Electric Diagram page 68

Hide thumbs Also See for 200L:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 43
Overview
10.3. Installation settings.
Re-access the installation's different settings:
• Date and time
Set the day and confirm. Proceed in the same way for the month, the year, the hour and the minutes.
Validate or not the automatic time change
• Operating ranges
This setting defines the authorised start-up ranges for the heat pump, the electric back-up and, if present, the
hydraulic back-up, based on the hot water requirements:
Permanent 24h/24h
Programming
• Connectivity
The water heater is compatible with the Cozytouch offer and with bridges using the iO-homecontrol®
protocol. The accessories that are required are: an Internet access box, the Cozytouch bridge (optional) and
the Cozytouch application which is free to download.
The Cozytouch app lets you control your water heater using your smartphone or tablet. Connect to the
application by following its instructions.
• Language
Can be set to French, English, Dutch, Spanish, Portuguese, German, Italian and Polish.
10.4. The settings to adjust during installation.
❶ Press and hold
• Air ducts (aeraulic operation):
This setting defines the type of aeraulic connection made:
Interior/Interior
Exterior/Exterior
Interior/Exterior
• Installation (for products with coil):
Thermodynamics only
Boiler backup
Solar backup
In "Boiler backup", you are next asked to define a preference concerning the priorities of operation between
the boiler and the heat pump according to 4 levels:
The backup will only be active at the end of heating for very low air temperatures (<7° C)
Heat pump priority
The backup will only be active at the end of heating and ± earlier depending on the air
Heat pump optimised
temperature The heat pump is active at the start of heating and ± later depending on the air temperature
Boiler optimised
The heat pump is active at the start of heating and for air temperatures > 10 ° C.
Boiler priority
66
Installation
Start-up at any time of the day,
Start-up only within the programmed period.
1st range duration: 4 hours < time < 14 hours;
Total duration of the 2 ranges: 8 hours minimum and 14 hours maximum.
The settings are accessible in INSTALLER MODE
Hold down the MENU button and turn the dial a half turn to the right.
To exit the installer mode, proceed in the same way or wait 10 minutes.
Make a
Access settings
1/2 turn
to the
right
Suction and discharge not connected to air ducts (ambient air)
Suction and discharge connected to air ducts (ducted air)
Discharge connected to an air duct (semi-ducted)
The internal heat exchanger is not used
The internal heat exchanger is connected to a boiler controlled by the product
The internal heat exchanger is connected to a solar system
Use
Maintenance
+
Warranty
Settings
Settings

Advertisement

Table of Contents
loading

This manual is also suitable for:

200l c270l270l c200 coil270coil

Table of Contents