Installation And Connections; Technical Features - Fermax MS-BOX User& Installer's Manual

Loft compact monitor
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION AND WIRING
Assembly
1
Standard connection - See installation diagrams included in the MS-BOX module
manual (manual code 97672)
F1
F2
M
V
V
M
+
-
L
CT
A
T
L
-
L:
data & audio.
+, -: power supply (18 Vdc).
V: live (coaxial - video).
M: shield (coaxial - video).
Ct: camera activation (10 Vdc).

TECHNICAL FEATURES

Power Supply
Consumption
Operating Temperature
Humidity
TFT
Resolution:
Compound signal 1 Vpp 75 Ω, 7 Mhz
Video Signal:
Dimensions
(Height x Width x Depth)
1 6
4
2
F1
F2
M
V
V
M
P1
+
-
L
CT
A
T
+
T, -:
A, +: extension Call connection ref. 2040,...
F1, F2:Additional functions (negative output).
Maximum current per pussbutton F1, F2: 50mA with
standby
making a call
with video
with audio and video
Flat Screen. 3.5" Diagonal
Horizontal: 480 Line TV - Vertical: 234 Line TV
:
Disassembly
P1
L
L +
call pushbutton at the apartment's door (P1).
241 x 133 x 39 mm -
1
90º
DISTRIBUIDOR VIDEO 2 SALIDAS
REF.2448
2 OUTPUTS VIDEO DISTRIBUTOR
+
R
1
5
(-)
V
M
V
M
+18
-
R1
75
-
18 Vdc
14mA
440 mA
120 mA
220 mA
[5 , +40 °C] - [41, +104 ºF]
[0 - 90%]
9,5" x 5.3" x 1,5"
2
+
2
6
4
3
V
M
V
M
12Vdc.