D X-2 100 Se ri es Ind ustr ia l 3G C lo ud Ro u ter
Controller
It's fixed to "MITSUBISHI PLC" in MC master mode.
Address Type
Address types would be D/M/S/X/Y, which D is a word type and M/S/X/Y are bit
types.
Slave Starting Address (decimal)
Set the slave starting address for read/write the registers in MITSUBISHI PLC.
_3
Bit
Invalid under MC master mode.
Device Starting Address (decimal)
Set up the device starting address (decimal, input range is from $2048 to
$4095). Must start at the beginning of a Device Starting Address with a "$" or
"M".
Length
Set the length, which is the number of the continuous address followed by the
starting address, ranging from 1 to 64.
Operation
Click the +/- button to add mapping or delete mapping.
Edit
Click an item of register mapping forms that can be edited.
3.4.4

RS485

RS-485 supports 6 working modes: Transparent mode, Slave mode, Master mode, Serial Server-TCP Server, Serial
Server-TCP Client and Serial Server-UDP Client. This section provides information of specific RS-485 port parameters
under different working modes. The basic parameters are presented in the table below.
Working Mode
Select the working mode for the current active serial port.
Baud Rate
Set the baud rate for the serial port. Options are 2400, 4800, 9600, 19200,
38400, 57600 and 115200.
Data Bits
Set port data bits as 7 or 8. When operating in Modbus RTU mode, the value can
only be set as 8.
Stop Bits
Set up the stop bits for the serial port. Options are 1 and 2.
Parity Bits
3 - 3 8
Description
Description
Default
MITSUBISHI
PLC
D
N/A
N/A
N/A
N/A
N/A
Default
Close
9600
8
1