Care, maintenance and repair

12 Care, maintenance and repair
ATTENTION!
- All cleaning, care, maintenance and repair work
may only be carried out with the generator switched
off.
- Always remove the spark plug connector from the
spark plug.
- No power consumer may be connected to the gene-
rator.
- Wait until the hot parts have cooled down.
- Never clean the machine with a water jet or flam-
mable products!
- Before putting the generator back into operation,
make sure that it is completely dry.
NOTE!
The warranty does not cover parts of the generator
that have been misused or negligently handled by
the operator. For full warranty coverage, the opera-
tor must operate the generator as described in the
manual.
Regular adjustments must be made to ensure pro-
per operation of the generator. Follow the instructi-
ons in the "Maintenance schedule".

12.1 Care by cleaning

The generator must always be kept in a clean condition.
ATTENTION!
- Never use solvents to clean plastic parts or painted
surfaces. The surface may become detached and
consequential damage may occur.
Use protective gloves!
NOTE!
Never use strong cleaning agents for any cleaning-
work. This can damage or destroy the device
All plastic parts and painted surfaces should be cleaned
with a soft, damp cloth and some neutral cleaner. Re-
move excess grease or leaked oil with a dry, lint-free
cloth.
Always keep the cooling fins clean and free.
22

12.2 Maintenance and repair

Maintenance and repair work may only be carried out by
qualified personnel.
If the generator does not function properly, contact a
specialist dealer or our customer service. The contact
details can be found in chapter 1.2 Customer service.
All protective and safety devices must be reinstalled im-
mediately after completion of repair and maintenance
work.

12.3 Maintenance schedule PG-I 42 SE

Maintenance inter-
Maintenance tasks
val / Operating
hours
- Check fuel level, check lines
for leaks, replace lines if
Before each use
necessary.
- Check engine oil level.
after the first 5
Changing the motor oil
hours
after 50 hours
Clean the air filter, replace if
necessary.
after 50 hours
Changing the motor oil
after 100 hours
Check the air filter, clean if
necessary.
after 100 hours
Check the muffler filter, clean
and replace if necessary.
after 100 hours
Check spark arrester, clean,
replace if necessary
after 100 hours
Change the oil, clean the
oil tank
after 250 hours
Clean combustion chamber
every 3 years
Replace fuel line
PG-I SE Series | Version 1.04