Fig. 6: Description of the battery
Fill engine oil
The generator is supplied without motor oil. Do not fill the
generator with fuel or attempt to start the generator be-
fore the oil is filled.
NOTE!
DO NOT attempt to start or start the engine until it has
been properly filled with the recommended type and
quantity of oil. If you damage the generator by not
following these instructions, your warranty will be voi-
ded.
NOTE!
The generator rotor has a sealed, pre-lubricated ball
bearing that requires no additional lubrication for the
life of the bearing.
Engine oil has a great influence on engine performance and
service life. SAE 10W-30 is recommended for general use
at all temperatures. Always use a 4-stroke engine oil that
meets or exceeds the requirements.
Place the generator on a flat surface to fill the oil.
A: Model PG-I 80 SE
Step 1: Loosen the screws on the left side of the mainte-
nance cover (Fig.7) and remove them.
Fig. 7: Open the cover
PG-I SE Series | Version 1.04
Step 2: Unscrew and remove the oil cover / dipstick.
Step 3: With the help of a funnel 1.1 liters of oil of type
Fill in 10W-30. Wait until the oil has completely
run into the container and the level has ad-
justed.
Step 4: Wipe the dipstick clean and replace it in the
opening. Do not rethread the dipstick!
Step 5: Pull the dipstick out again and check the engine
oil level. The engine oil level should be be-
tween the minimum and maximum mark on the
dipstick.
Step 6: Top up engine oil if the level is too low.
Fig. 8: Fill engine oil
Step 7: Replace the cap / dipstick and secure it.
B: Model PG-I 42 SE
Step 1: Remove the oil filler cap / dipstick to top up oil.
Measuring stick
Fig. 9: Remove closure of the oil filler neck
Step 2: With the help of a funnel 0.6 liter oil of the type
Fill in 10W-30.
Fig. 10: Fill in oil
Step 3: Wait until the oil has completely run into the conta-
iner and the level has adjusted. Then check the
correct oil level (1, Fig. 11).
Preparation and set-up
Drain plug