10.3 12 V DC Outlet
The 12 V DC socket can be used with the supplied char-
ging cable, USB charger and other standard 12 V DC
plugs. The DC output is unregulated and may damage
some products. Make sure that the input voltage range of
your accessories is at least 12-24 V DC. When using the
DC outlet, set the economy mode switch to "OFF"..
NOTE!
- Do not operate a device while it is connected to the
12 V DC outlet.
- Prolonged contact with engine exhaust fumes may
result in serious or fatal injury.
- Do not place an appliance on the generator exhaust
side when charging. Extreme heat from exhaust ga-
ses can damage the unit and cause a fire.

10.4Switch of the generators

Step 1: Switch off and disconnect all electrical loads. Ne-
ver start or stop the generator when electrical
appliances are connected or switched on.
Step 2: Allow the generator to idle for a few minutes to
stabilize the internal engine and generator tem-
peratures.
Step 3: Set the fuel tap to "OFF".
Step 4: Run the engine until the fuel shortage has stop-
ped the engine. This usually takes a few
minutes.
Step 5: Set the motor switch to "OFF".
ATTENTION!
Always make sure that the fuel valve and motor
switch are in the "OFF" position when the device is
not in use.
NOTE!
The motor is used for a period of two (2) weeks or lon-
ger. For information on proper storage of the engine
and fuel, see the Storage section.

10.5Overload mode

The overload indicator switches on when the load is ex-
ceeded. When the maximum load is reached, the LED
flashes and cuts off power to the sockets. Turn off the
generator, wait for the light to go out, and restart the ge-
nerator to restore power.
PG-I SE Series | Version 1.04

Start generator PG-I 80 SE

11 Start generator PG-I 80 SE
NOTE!
Check the lubricant level on a flat surface with the en-
gine off before each use of the generator.
If the position of the generator is not level, the unit
may not start or may turn off during operation.
NOTE!
Do not place the power generator directly on the
ground when using the unit on grassy areas or in
areas with dense vegetation. Doing so may cause
grass discoloration and/or localized soil damage.
Step 1: Disconnect all consumers from the power gene-
rator.
Step 2: Set the voltage selector switch (optional) to adjust
the voltage requirements for the application.
Step 3: Set the Eco switch to OFF. (If you want to use the
Eco system, set the Eco switch to ON after the
engine warms up after 2 or 3 minutes.
Fig. 19: ECO-Button
Step 4: Turn the multiswitch to the position START.
Fig. 20: Multiswitch
Electrical start
Set the motor switch to START and hold for 5 seconds.
When the engine starts, the starter motor stops automa-
tically. If the engine does not start, wait at least 10 se-
conds before operating the starter again.
19