Preparation And Set-Up; Preparation Pg-I 42 Se And Pg-I 80 Se - unicraft PG-I SE Series Operating Instructions Manual

Table of Contents

Advertisement

Preparation and set-up

NOTE!
The closed fuel tap prevents the carburettor from fil-
ling up with fuel during storage and transport.
To use up the remaining fuel, turn the fuel tap to "O"
and leave the engine running until it switches itself off
after the remaining fuel has been used up.
Choke
The choke is used for a cold start (when the engine is
cold). Pull the lever out completely to start the motor. Af-
ter the motor has warmed up sufficiently and stable ope-
ration has been achieved, push the lever back. It is not
necessary to use the choke when starting an motor that
is already warm.
Socket 230V AC
The socket can deliver a power of 230V continuously.
8
Preparation and set-up
Use protective gloves!
Wear safety boots!
Wear protective clothes!
CAUTION!
Danger of crushing!
If you work improperly on the generator, there is a
risk of injury to fingers and hands.
- Observe the weight of the generator. Ensure stable
supports and support devices.en.
Unpacking the generator
Step 1: Place the carton on a stable and level surface.
Step 2: Remove the packaging from the generator.
Step 3: Inspect the generator and ensure that it has not
been damaged in transit. If transport damage is
found, contact customer service or the dealer. In
this case, do not fill the generator with fuel or at-
tempt to start it.
12
8.1 Preparation PG-I 42 SE and PG-I 80
SE
Connect battery
DANGER!
To reduce the risk of electric shock or explosion, do not
short-circuit the battery terminals or charge in a sealed
container. Keep sparks and flames away.
DANGER!
Keep metal objects away from the battery terminals.
Metal objects can connect from one terminal to another.
Short circuiting the battery terminals can cause sparks,
burns or fire. '"
DANGER!
The battery may need to be charged before the genera-
tor can be started with the engine switch or pull starter.
Once the generator is started, the battery is charged
while the unit is running.
The battery cables must be connected before the power
generator can be operated.
Use the following steps to connect the battery cables:
Step 1: Loosen the screws on the side of the right mainte-
nance cover (Fig.5) and remove it (PG-I 80 SE
only).
Fig. 5: Open cover PG-I 80 SE
Step 2: First connect the red cable to the positive pole (+)
and then the black cable to the negative pole (-
). Make sure that all connections are secure.
Step 3: Secure the terminals with the rubber covers (if
present).
PG-I SE Series | Version 1.04

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pg-i 42 sePg-i 80 se67064206706800

Table of Contents