Assembly Instructions

STEP 1: Attach a 5/8" water supply
hose to inlet connector. Minimum
flow should be 6 or 10 gpm
depending on model of machine.
STEP 4: Check engine and pump
oil level by removing oil dipstick,
making sure oil is on proper
indicator marking. Oil should be
visible one half way up sight glass
located at the end of pump
(SAE 10W-40 non-foaming).

Battery Installation

Due to Federal Regula-
tions concerning shipment
of corrosive chemicals,
batteries are not shipped
with this machine.
Local purchase of battery will be the responsibility of
the owner. Automotive type 12 Volt Group 24 battery is
recommended for placement within the weather
resistant box. Follow safety and installation instructions
furnished with the battery.
10
Spray Wand
Safety
Latch
High Pressure
STEP 2: Attach wand to spray gun
using teflon tape on threads to
prevent leakage. Attach swivel
connector on discharge hose to
spray gun using teflon tape on
threads. Attach swivel connector on
high pressure hose to spray gun
using teflon tape on threads.
Engage safety latch to prevent from
triggering gun when inserting high
pressure nozzle.
STEP 5: Fill red gasoline tank. Fill
green fuel oil tank. Do not confuse
gasoline and fuel oil (diesel) tanks.
Keep proper fuel in proper tank.
DANGER/ POISON
FLUSH EYES
IMMEDIATELY
WITH WATER
SHIELD
SULFURIC
EYES
ACID
NO
EXPLOSIVE
SPARKS
CAN CAUSE
GASES
CAN CAUSE
BLINDNESS OR
FLAMES
BLINDNESS OR INJURY
SMOKING
SEVERE BURNS
KEEP OUT OF THE REACH OF CHILDREN. DO NOT TIP. KEEP VENT CAPS TIGHT AND LEVEL.
Landa PGDC Operator's Manual 8.916-596.0 - BF
Spray
Gun
Hose
Gasoline
Burner Fuel
Red Cable is attached to battery (+) positive terminal,
black cable is connected to battery (-) negative
GET
terminal.
MEDICAL
HELP
FAST
Black - Negative
Terminal
Red + Positive
Terminal
STEP 3: Attach high pressure hose
to discharge nipple using quick
coupler. Lock coupler securely into
place by pulling back coupler collar
and inserting it into discharge
nipple, then pushing collar forward
to lock in place.
STEP 6: Install proper battery
making sure that the red cable is
attached to the positive terminal.
Use a 12V Group 24 battery on all
models except 4-40321 and 5-
35321E. These models use a U1
30 amp garden tractor style battery.
High
Pressure
Hose
Discharge
Nipple
Black
Red