  • Page 1 User-Service Manual Joerns Advanced Surfaces ® Dolphin Fluid Immersion Simulation® System, Dolphin Pediatric Fluid Immersion Simulation® System To avoid injury, read user’s manual before using. *Representative image of the Dolphin Fluid Immersion Simulation System.
  • Page 2: Important Precautions

    Failure to do so could result in user manual and contacting Joerns Healthcare if personal injury or equipment damage. anything in this manual is unclear. Joerns will not be held responsible for any injuries resulting from failure • Immediately after using the Dolphin Fluid Immersion to comply with the instructions and precautions in this Simulation System, unplug it from its power source.
  • Page 3 Compliance Solutions ® Matching the right bed components in order to meet regulatory guidelines can be complex. That is why Joerns offers a wide array of compliance options. We assist customers in selecting compliant accessories recommended for their specific bed model.
  • Page 4: Table Of Contents

    Control Unit Therapy Mattress and Specialty Surface System Specifications ...............................15 Weight Safe Working Load Dimensions Electrical Specifications Environmental Conditions Control Unit Agency Approvals Call for Assistance ..............................15 Appendix A ..................................16 Warranty ..................................20 © 2014 Joerns Healthcare • 6110109 RevG • 14-2640...
  • Page 5: Introduction

    Wheelchair cushion weight capacity only; total weight must not exceed wheelchair manufacturers’ specified load capacity, and when paired with an appropriate surface. © 2014 Joerns Healthcare • 6110109 RevG • 14-2640...
  • Page 6: Shear And Friction Reduction

    • A microprocessor and proprietary software analyzes improved blood flow compared to traditional surfaces. the patient’s shape in a 3D volumetric format. • Continuously monitors the surface more than 100 times per second for any patient movement. © 2014 Joerns Healthcare • 6110109 RevG • 14-2640...
  • Page 7: Therapy Mattress And Specialty Surface Features

    Wheelchair cushion weight capacity only; total weight must not exceed wheelchair manufacturers’ specified load capacity, and when paired with an appropriate surface. © 2014 Joerns Healthcare • 6110109 RevG • 14-2640...
  • Page 8: Cpr

    The Chair/Stretcher mode should only be selected the length of the body parallel to the length of the when using a specialty surface. mattress. © 2014 Joerns Healthcare • 6110109 RevG • 14-2640...
  • Page 9 AC power, the Storage Switch must be in transfers or repositioning. Autofirm is not a therapy the Battery On position. mode. To override the Autofirm mode, press the Autofirm button again. © 2014 Joerns Healthcare • 6110109 RevG • 14-2640...
  • Page 10: Grounding Instructions

    Feedback LED scale will be amber. Should the system be outside of normal parameters, the LED scale will move from amber to red, indicating a potential need to manually adjust with Comfort Adjust arrows. © 2014 Joerns Healthcare • 6110109 RevG • 14-2640...
  • Page 11: Setup

    • Place the patient on the wheelchair cushion and the appropriate position based on the patient’s allow system to optimize. clinical condition. 2. Select the highest or most firm Comfort Adjust setting. © 2014 Joerns Healthcare • 6110109 RevG • 14-2640...
  • Page 12: Troubleshooting

    • Ensure that the Storage Switch is turned to the Battery on position. • Ensure that the CPR valve is closed. • Ensure that the CPR flag plugs are inserted (if applicable). © 2014 Joerns Healthcare • 6110109 RevG • 14-2640...
  • Page 13: Patient Positioning And Comfort

    The risk of gradual movement and/or sinking into hazardous positions of entrapment and/or inadvertent bed exit may be increased due to the nature of these products. © 2014 Joerns Healthcare • 6110109 RevG • 14-2640...
  • Page 14: General Cleaning

    Wheelchair cushion weight capacity only; total weight must not exceed wheelchair manufacturers’ specified load capacity, and when paired with an appropriate surface. © 2014 Joerns Healthcare • 6110109 RevG • 14-2640...
  • Page 15: Storage And Care

    Minimum weight capacity1..5 lbs (2.3 Kg) Call for Assistance If you have any questions or require service on a product, please call Joerns Healthcare at: North America - 800.862.0270 Europe - (+31) 30.6363.700 © 2014 Joerns Healthcare • 6110109 RevG • 14-2640...
  • Page 16 IEC 61000-3-2 connected to the public low-voltage power supply network that supplies Voltage fluctuations / buildings used for domestic purposes. flicker emissions Complies IEC 61000-3-3 © 2014 Joerns Healthcare • 6110109 RevG • 14-2640...
  • Page 17 IEC 61000-4-8 Note: Uτ is the a.c. mains voltage prior to application of the test level. © 2014 Joerns Healthcare • 6110109 RevG • 14-2640...
  • Page 18 If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the Auto Vector Fluid Immersion Simulator. Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m. © 2014 Joerns Healthcare • 6110109 RevG • 14-2640...
  • Page 19 Note 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. Note 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects, and people. © 2014 Joerns Healthcare • 6110109 RevG • 14-2640...
  • Page 20: Warranty

    (compressors, valves, printed circuit boards, hoses, any product which is found by Joerns to be defective. and couplers). Damages arising from improper use will When requested by Joerns, parts must be returned for not be covered by this warranty.