  • Page 1 User-Service Manual Joerns Bed Frames ® WeCare™ Bed To avoid injury, read user’s manual before using.
  • Page 2: Important Precautions

    Place bed on its side versus working under it. Failure to do so each so that gap between them is large enough for trunk and could result in injury or death. Note: In case of unexpected movement, unplug bed from any outlet. © 2021 Joerns Healthcare • 6110429 RevC • 21-2257...
  • Page 3 ® specifically for the WeCare bed and it is locked in place. surgical equipment and similar devices. Do not route high Failure to lock assist devices may result in injury or death.
  • Page 4: Table Of Contents

    That is why Joerns offers a wide array of compliance options. We assist customers in selecting compliant That focus includes not only the challenge of achieving...
  • Page 5: Features And Specifications

    The identification label is Class II Equipment located on bed frame under the mattress support platform foot section. Functional Earth (ground) Pinch Point © 2021 Joerns Healthcare • 6110429 RevC • 21-2257...
  • Page 6: Assembly

    5. Insert safety pin on left and right sides, 2 pins total (Figure 5). Be sure to route the actuator cables through the nearest safety pin bail (Figure 6). Figure 5 Figure 1 Figure 6 © 2021 Joerns Healthcare • 6110429 RevC • 21-2257...
  • Page 7 Plug-in power cord to power source and raise the bed frame. Note: Watch for obstructions. Figure 10 Install bed panels per the following instructions. Figure 11 Figure 7 Figure 12 Figure 8 Figure 9 Figure 13 © 2021 Joerns Healthcare • 6110429 RevC • 21-2257...
  • Page 8 WeCare bed platform has four IV sockets as ® standard equipment. There are two sockets at head end of bed and two at foot end (Figure 17). The IV sockets are used with Joerns IV poles and most ½" IV Socket IV poles. Figure 17...
  • Page 9: Operation

    Joerns® Bed Frames WeCare™ Bed Operation Pendant Operation (Figure 18) Your Joerns WeCare bed comes with a pendant (Figure 18).The pendant allows the patient/resident to Back Operation operate the bed. 1. Push button to raise back 2. Push button to lower back Warning: Possible Injury or Death.
  • Page 10: Servicing

    2. Switch pendant with a new one or one from a bed that is functioning normally. 3. If these steps fail to resolve the problem, call Technical Support at 800-826-0270. Figure 22 © 2021 Joerns Healthcare • 6110429 RevC • 21-2257...
  • Page 11: Troubleshooting

    4. Make sure each inspection includes the underside of the bed frame and mattress support platform. Check joints between sleep surface sections for loose fasteners. © 2021 Joerns Healthcare • 6110429 RevC • 21-2257...
  • Page 12: Cleaning

    Do not submerge the pendant in liquid. for any cracking, bending, or hole enlargement. If found, contact Joerns Technical Support at Your Joerns bed has a durable, baked-on epoxy finish, 800.826.0270, remove the bed from service easily cleaned with mild solution of antiseptic cleaner immediately, and replace the affected parts.
  • Page 13: Accessories

    5. Remove the screws using the #2 Phillips screwdriver; do not discard the screws. 6. Position and insert the mattress stops in the holes provided. Reinstall the screws removed in step 5. © 2021 Joerns Healthcare • 6110429 RevC • 21-2257...
  • Page 14 WeCare bed, particularly when it is lowered installation of the trapeze adapter could alter or onto its casters. Note: The WeCare™ bed is not dislodge the head panel position, increasing the risk of designed for use as resident/patient transport injury or suffocation.
  • Page 15 Some trapeze systems may not be holder at that height are especially at risk. Failure to do suitable for use with the WeCare bed, due to its so could result in injury or death. low operating height.
  • Page 16: Warranty

    +44 (0)844 811 1156 +31 (0)30 6363799 Charlotte, NC 28273 (P) 800.966.6662 (P) 866.546.1151 +44 (0)844 811 1157 (P) 800.826.0270 (F) 800.232.9796 (F) 519.451.8662 (F) 800.457.8827 www.joerns.com • email: info@joerns.com © 2021 Joerns Healthcare • 6110429 RevC • 21-2257 • MAN1...