Service Operations; Checking The Area; Intervention Procedure; General Work Area - Saneo 12000 BTU Manual

Table of Contents

Advertisement

Available languages

Available languages

Illustrations are not contractual.
SELECTIVE COLLECTION OF ELECTRICAL AND ELECTRONIC WASTE
Electrical products should not be disposed of with household products. According to the European Directive
2012/19/EU for the disposal of electrical and electronic equipment and its implementation in national law, used
electrical products must be collected separately and disposed of at the collection points provided for this purpose.
Contact your local authorities or dealer for recycling advice.
WARRANTY TERMS AND CONDITIONS
This product is guaranteed for a fixed period of time with the distributor from the date of purchase against any failure
resulting from a manufacturing or material defect. This warranty does not cover defects or damage resulting from
improper installation, improper use or abnormal wear and tear of the product.
The device must be returned in its original packaging and accompanied by the receipt, subject to proper handling.
Therefore, observe the operating instructions and safety instructions given above. In addition, we cannot guarantee
your device if you or a third party have made any modifications or repairs.

SERVICE OPERATIONS

This document describes the precautions for use by personnel responsible for service operations.
Any person required to work on a refrigerant circuit should hold a valid and up-to-date certificate from an assessment
authority accredited by the industry and recognising his competence to handle refrigerants safely, in accordance with
the assessment specification recognised in the industry sector concerned.
Service operations must only be carried out in accordance with the recommendations of the equipment manufacturer.
Maintenance and repair operations requiring the assistance of other qualified persons must be carried out under the
supervision of the person competent for the use of flammable refrigerants.

- Checking the area:

Before starting work on systems containing flammable refrigerants, safety checks are necessary to ensure that the
risk of ignition is reduced. For repairs to the refrigeration system, the following precautions must be observed before
working on the system.

- Intervention procedure

Interventions must be undertaken as part of a controlled procedure in order to minimise the risk of flammable gas or
vapour during the work.

- General work area

All maintenance personnel and other persons working in the local area must be informed of the nature of the work
performed. Any work in confined spaces must be avoided. The area surrounding the workspace must be divided into
sections. Ensure that conditions within the area have been made safe by controlling flammable materials.
- Checking the presence of refrigerants
The area must be checked with an appropriate refrigerant detector before and during the work to ensure that the
technician is aware of the existence of potentially explosive atmospheres. Ensure that the leak detection equipment
used is suitable for use with flammable refrigerants, i.e. it does not produce sparks, is properly sealed and is
intrinsically safe.
- Presence of fire extinguishers
If work causing heat is to be carried out on refrigeration equipment or its associated parts, appropriate fire protection