2.8 E9: EEPROM error (For all models)
2.8.1 Digital display output
E9
2.8.2 Description
EEPROM error
The system stops running.
Error code is displayed on the outdoor unit PCB.
2.8.3 Trigger / recover condition
Trigger condition: Unable to read the EEPROM when startup.
Recover condition: EEPROM goes back to normal.
Reset method: Manually restart.
2.8.4 Possible causes
The EEPROM is not inserted well
Damaged main PCB.
2.8.5 Procedure
Check whether the EEPROM is inserted well.
2.9 E.9.: Compressor parameters mismatch (For all modes)
2.9.1 Digital display output
E.9.
2.9.2 Description
Main control chip detect the power setting number mismatch the model, the unit will display E.9. error.
The system stops running.
Error code is displayed on the outdoor unit PCB.
2.9.3 Trigger / recover condition
Trigger condition: Main control chip detect the power setting number mismatch the model.
Recover condition: Main control chip detect the power setting number match the model.
Reset method: Manually restart.
2.9.4 Possible causes
Power number setting mistake.
Damaged main PCB.
E9
Yes
Replace outdoor main PCB.
No
Insert the EEPROM well