EVERPURE
4FC & 7FC COLDRINK
®
4FC & 7FC Coldrink 1 System(s)
SELECTING A MOUNTING LOCATION
1. Give consideration to the weight of the unit when operating (filled with water). Operating weight of the Coldrink systems are:
• 4FC System 1 - 16 lbs (7.26 kg)
• 4FC System 2 - 29 lbs (13.15 kg)
• 4FC System 3 - 37 lbs (16.79 kg)
• 4FC System 4 - 43 lbs (19.50 kg)
2. The location should allow for:
• Minimum clearance of 2.5 inches (6.3 cm) under the cartridge(s) so it can be lowered for removal and replacement.
• Adequate space for "in" and "out" water line connections.
• Be near a drain for flushing and near a 110V outlet if the accessory (sold separately) Everguard
is used.
OPERATING SPECIFICATIONS*
Combined
Replacement
Model Name
Cartridges
Coldrink System
4FC
1 - 4FC
Coldrink System
7FC
1- 7FC
Coldrink System
4FC
2 - 4FC
Coldrink System
7FC
2 - 7FC
Coldrink System
4FC
3 - 4FC
Coldrink System
7FC
3 - 7FC
Coldrink System
4FC
4 - 4FC
Coldrink System
7FC
4 - 7FC
FILTRATION & PROCESSING SOLUTIONS
SERIES FILTER SYSTEMS
®
4FC & 7FC Coldrink 2 System(s)
Flow Rate
Capacity
2.5 gpm
15,000 gal (56,781 L)
(9.46 Lpm)
2.5 gpm
25,000 gal (94,635 L)
(9.46 Lpm)
5.0 gpm
30,000 gal (113,562 L)
(18.92 Lpm)
5.0 gpm
50,000 gal (189,270 L)
(18.92 Lpm)
7.5 gpm
45,000 gal (170,343 L)
(28.39 Lpm)
7.5 gpm
75,000 gal (283,905 L)
(28.39 Lpm)
10.0 gpm
60,000 gal (227,124 L)
(37.85 Lpm)
10.0 gpm
100,000 gal (378,541 L)
(37.85 Lpm)
4FC & 7FC COLDRINK SERIES SYSTEMS IO GUIDE
4FC & 7FC Coldrink 3 System(s)
• 7FC System 1 - 19 lbs (8.62 kg)
• 7FC System 2 - 35 lbs (15.8 kg)
• 7FC System 3 - 45 lbs (20.2 kg)
• 7FC System 4 - 55 lbs (24.95 kg)
*For individual cartridge specifications, refer to cartridge literature.
Temperature:
35-100°F (2-38°C)
Pressure:
10-125 psi (0.7-8.6 bar), non-shock
For cold water use only.
4FC & 7FC Coldrink Systems Tested and Certified by NSF International against NSF/ANSI
Standards 42 and 53 for the reduction of:
Standard No. 42 — Aesthetic Effects
Aesthetic Effects
Bacteriostatic Effects
Chemical Reduction
Taste and Odor
Chlorine
Mechanical Filtration
Nominal Particulate Class I
4FC & 7FC Coldrink 4 System(s)
Low Pressure Alarm (LPA)
TM
Standard No. 53 — Health Effects
Mechanical Filtration
Turbidity
Cyst