Removing The Main Bearing - Weatherford MP-16 Operation & Maintenance Manual

Triplex pump, two piece fluid end - 5,000 psi
Table of Contents

Advertisement

5.2.5 Removing the Main Bearing

Use this guide to remove the main bearing without removing the crankshaft from the
floating carrier or to remove the main bearing from a crankshaft that has already been
removed from the power frame.
Remove the main crankshaft assembly as
1
per 5.2.4, and support the crankshaft
assembly so that the load is not resting on
the main bearings.
Loosen the main bearing. To do so, loosen
2
the bolts on the outer retainer 2 or 3 turns,
and then inject grease into the grooves in
the race until the bearing becomes loose on
the shaft.
weatherford.com
Pump and Fluid Systems
Chapter 5: Assembly/Disassembly
70
MP-16 2-Piece 5000 psi January 2013

Advertisement

Table of Contents
loading

Related Products for Weatherford MP-16