4.7.3 Installing the Valves

Ensure that the taper, valve, seat and cover
1
are clean, dry and free of nicks, burrs or
cracks as per 4.5.2: Pre-Installation
Procedure.
Use a valve seat driver or wood block to
2
insert the valve seat into position, and press
to obtain an initial seal. Exercise care not to
strike the valve seat directly with a metal
hammer or steel bar.
Install the valve into the seat and center the
3
spring on the valve.